55
Programming Devices
Section 3-4
3-4-1
Programming Consoles
The following three Programming Console are available:
• CQM1H-PRO01
• CQM1-PRO01
• C200H-PRO27
Programming Console Connections
3-4-2
CX-Programmer
The CX-Programmer versions that can be used with the Customizable
Counter Unit are given in the following table.
Note
The functional limitations when using the CX-Programmer with the Customiz-
able Counter Unit are shown in the following table.
• Functional Limitations
Port at the
Customizable
Counter Unit
Programming
Device
connection
switch setting
Programming
Console model
Type of network
(serial
communications
mode)
Cables
Model number
Length
Peripheral port
ON
C200H-PRO27
Programming
Console bus
(automatic recog-
nition)
C200H-CN222
and CS1W-CN114
2 m and 0.05 m
C200H-CN422
and CS1W-CN114
4 m and 0.05 m
CS1W-CN224
2 m
CS1W-CN624
6 m
CQM1-PRO01
Cable included
with Programming
Console and
CS1W-CN114
2 m and 0.05 m
CQM1H-PRO01
(Included with Pro-
gramming Con-
sole.)
2 m
Name
Model number
Computer
Serial
communications
mode
Model setting on
the CX-
Programmer
Functional
limitations
CX-Programmer
Ver. 1.2 or later (on
CD-ROM)
WS02-CXPC1-E
IBM PC/AT or
compatible
OS: Microsoft
Windows 95 or 98
Peripheral bus
CQM1H-CPU61
Yes
Item
CX-Programmer Ver. 1.2 or later
Selected device type
Select CQM1H-CPU61.
Editing the PLC Setup
Not supported. (The settings in DM 6600 to DM 6655
must be made in the PLC Memory Window.)
Memory displays
Displayed for CQM1H.
Содержание CS1W-HCA12-V1
Страница 2: ......
Страница 6: ...vi...
Страница 20: ...xx Conformance to EC Directives 7...
Страница 38: ...18 Models and System Configurations Section 1 2...
Страница 78: ...58 Fail safe Circuits Section 3 5...
Страница 138: ...118 AR Area Section 6 4...
Страница 204: ...184 Improved Instructions Section 7 14...
Страница 222: ...202 Cycle Time Section 8 3...
Страница 240: ...220 Troubleshooting Flowcharts Section 9 5...
Страница 244: ...224 Precautions when Using the CX Programmer Appendix A...
Страница 252: ......
Страница 253: ......