Page 1 of 33 

 

V1.1 

 

 

 

HAL-HPC601 

Handheld Particle Counter 

 

 

 

Operational Manual 

 

 

 

 

 

 

 

 

 

7970 Cherry Ave., Suite 303 

Rancho Cucamonga, CA 91730 USA 

Phone: (866) 438-4258 

Fax: (855) 402-9190 

[email protected] 

http://haltechnologies.com 

 

 

 

Содержание HAL-HPC601

Страница 1: ...f 33 V1 1 HAL HPC601 Handheld Particle Counter Operational Manual 7970 Cherry Ave Suite 303 Rancho Cucamonga CA 91730 USA Phone 866 438 4258 Fax 855 402 9190 Info haltechnologies com http haltechnolog...

Страница 2: ...Page 2 of 33 V1 1 This page intentionally left blank...

Страница 3: ...tion 12 2 1 Handheld Unit Overview 12 2 2 Key Functions 12 2 3 Graphical User Interface GUI 13 2 3 1 Main Screen 13 2 3 2 Measure Screen 14 2 3 3 Browse Screen 16 2 3 4 Settings Screen 17 2 3 5 Modify...

Страница 4: ...Page 4 of 33 V1 1 Version Table Date Version Comment February 10 2017 1 1 Added Data Downloader instructions December 20 2016 1 0 Formal Release...

Страница 5: ...oducts it describes at any time without notice or obligation Published in the United States of America Copyright 2016 by Hal Technology All rights reserved No part of the contents of this manual may b...

Страница 6: ...hat may be damaged by improper handling The warranty is void for any unauthorized opening of the instrument Environmental Requirements To avoid accidents or damage to the instrument please avoid using...

Страница 7: ...33 V1 1 annually at least Please contact Hal Technology to schedule your calibration or any services needed The HAL HPC601 can only be serviced at Hal Technology or by a Hal Technology authorized pro...

Страница 8: ...ight and generate electrical pulses proportional to the size of the incident particles The HAL HPC601 is a completely self contained particle counter that is no other parts are required to start monit...

Страница 9: ...ons are available to include Mass Concentration and Particulate Matter measurements Optional accessories also include a digital temperature relative humidity and pressure probe as well as an isokineti...

Страница 10: ...ure accurate measurement Up to 260 unique location labels No less than 6 hours of continuous operation Bluetooth Wireless printing capabilities Compatible with Window XP 7 8 10 operation systems 1 2 S...

Страница 11: ...battery discharged Interface USB Bluetooth Power Rechargeable Lithium ion battery 7 4V 5200mAh AC adapter 100 240VAC to 9VDC 1 5A Dimension 93 W 180 H 48 D mm Weight Approximately 900 grams Environme...

Страница 12: ...rface is composed of a six key interface ENTER BACK Each button controls the following features Power button While the unit is off press and hold the power button for approximately 2 seconds to turn o...

Страница 13: ...charge cycle and becomes steady after the charge cycle is finished Ethernet Interface This feature is not standard for the HPC601 and is a future option 2 3 Graphical User Interface GUI 2 3 1 Main Sc...

Страница 14: ...reen one can navigate to the Settings Screen by pressing the UP key the Browse Screen by pressing the DOWN key or start taking data by pressing the RUN STOP key The Measure Screen also shows the statu...

Страница 15: ...ample Duration and Sample Interval If either the Sample Duration or Sample Interval is to be set below 5 seconds the other must be greater or equal to 5 seconds For example if you want a Sample Durati...

Страница 16: ...n Figure 5 Measurement Procedure for the HPC601 The total time for an ensemble of measurements can be calculated as 2 3 3 Browse Screen Figure 6 shows the Browse Screen of the HPC601 From this screen...

Страница 17: ...From this screen one can navigate to the Browse Screen by pressing the UP key the Measure Screen by pressing the DOWN key or enter the settings screen by pressing the ENTER key All the unit s paramet...

Страница 18: ...e editing 00 00 The UP and DOWN keys will now edit the Sample Duration appropriately When finished press the BACK key to stop editing 00 00 Particle Sizes Modify particle sizes on Channels1 6 Sample P...

Страница 19: ...l allow the user to modify the following parameters over the following ranges Start Delay 00 00 to 59 59 Sample Interval 00 00 to 59 59 Sample Duration 00 00 to 59 59 Number of Samples 0 to 500 Materi...

Страница 20: ...et to Avg only the average across the number of samples will be stored When setting this number keep in mind the run time of the entire sampling procedure Depending upon the battery charge the user ma...

Страница 21: ...the following standard Count Modes Cumulative Counts Differential Counts Counts Per Liter Counts Per Cubic Foot Counts Per Cubic Meter and the following optional Count modes Mass Concentration Partic...

Страница 22: ...following preset alarm levels ISO 3 FS209E 1 ISO 4 FS209E 10 ISO 5 FS209E 100 ISO 6 FS209E 1 000 ISO 7 FS209E 10 000 ISO 8 FS209E 100 000 ISO 9 FS209E 1 000 000 The custom alarm level is a count limit...

Страница 23: ...ed The optional Bluetooth printer is required to print If you would like to purchase the printer contact Hal Technology info haltechnologies com Bluetooth Settings The Bluetooth settings are for the o...

Страница 24: ...uired contact services haltechnologies com The Clear Last Record option is available in case the unit were to lose power while saving data If this were to occur it is possible the last record could be...

Страница 25: ...the instructions in the file named Readme txt that is usually provided on the compact disc After successful installation it is preferable to have the HPC601 powered off when using the software to dow...

Страница 26: ...o to the Factory Settings page under Settings and Clear the last record If this does not fix the problem try a Factory Reset all memory will be cleared The unit does not appear to be saving my changes...

Страница 27: ...of 33 V1 1 Printer does not print 1 Ensure the printer is in working order turned on and has thermal paper 2 Ensure Bluetooth is enabled on the HPC601 3 Run a connection test from the Bluetooth Settin...

Страница 28: ...un specified environmental condition Abnormal operation due to required instrument calibration Limitation of Warranty A Hal Technology warrants that all equipment shall be free from defects in materia...

Страница 29: ...Hal Technology s option be terminated C Warranty repairs shall be completed at a Hal Technology authorized service location by an authorized service technician or on site at buyer s facility by a Hal...

Страница 30: ...the warranty period Buyers may select a faster method of shipment at their own expense Contact Information HAL TECHNOLOGY LLC 7970 Cherry Ave Suite 303 Rancho Cucamonga CA 92336 USA Phone 866 438 4258...

Страница 31: ...a CA 92336 USA Fax 855 438 4258 toll free Or send relevant registration information to the email address below services haltechnologies com User Registration Form Company Contact Person Address City S...

Страница 32: ...eshold but not the 10 0 m threshold also meets the 0 3 m threshold So both the 0 3 m and 2 5 m channel counts are incremented Differential Counts The relative number of counts for a channel referenced...

Страница 33: ...Page 33 of 33 V1 1 sample interval The sample interval can be set between 00 00 and 59 59 Time Passing Wait Sample Wait Sample Wait Sample Wait Sample...