Using the Remote Control
81
the Options Menu and select Connect,
nection has been established.
Establishing a Remote Connection
To establish a connection with the remotely located Omnia-3, return to
which brings up a list of connections you have defined. Double-click on the name of the desired connection, or
highlight it to select it and press OK. The connection will be established after a short pause, and you should see
the bargraph meters become active when a con
Omnia-3 Remote Control after connection is made. Note that the currently selected Preset and
the Omnia's actual System time are being displayed.
Use Cancel to leave the dialog box without making any connection.
You can choose to have the program automatically establish a connection by going to the Options Menu,
selecting Auto-Connect to Last. Then the program will always connect to the Omnia-3 using the last-used
startup connection entry.
Note that if you have not entered a Password while editing the connection type, you will be prompted for it each
time you connect to the Omnia!
Terminating a Connection
From the Options Menu, select Disconnect. Closing the program will also terminate any connections.
Remote Features
The Remote Control Program for Omnia-3 provides all the features of the front panel, displayed in an easy-to-
use format. It adds these enhancements:
•
Multiple control windows may be open at the same time.
•
The ability to save, load, and print presets and system parameters to the computer. (in the File Menu)
This is very handy for reference and backup purposes.
•
The ability to edit and load Trigger Scripts as described starting on Page 83.