63
Technical note: the Omnia 3 Remote Control communicates with the Omnia 3 using a Telnet session on Port
23. If you are unable to communicate with the Omnia through a network firewall, the first thing to check is
whether traffic on port 23 is being permitted.
Enter the password for the unit in the Password box. If nothing is entered, you will be asked for the password at
the time you connect to the remote Omnia. The default passwords for Ethernet remote connections are the same
as the front panel passwords:
Normal: “vito” (all lower case)
Engineer: “tomtom” (all lower case)
The Remote Control software allows multiple connection profiles to be created so that a mix of connection
types (Direct,
nicating with
Note: These connection settings are stored in a small binary file named
located in the same folder
Connecting via Ethernet Network
For Network connections, check the
Connect over Ethernet
box and enter the IP address of the Omnia-3fm
Turbo in the box provided. The TCP/IP address entry format is: xxx.xxx.xxx.xxx. The TCP/IP address of the
Omnia-3 Ethernet hardware interface is set during initial configuration.
Serial, TCP/IP) may be used. This allows the program to easily support commu
different Omnias at different locations, connected by different means.
When all items have been entered, select OK.
connect.dat
as the remote program.