Maintenance Manual
Test Programs
3-17
Page
Test No./
Test Name
Function Outline
No. 15
Orientation
flat and
notch
positions
check
<Orientation flat alignment adjustment>
This program can be used to check and adjust the orientation flat and notch positions for each wafer
diameter.
Insert a wafer into any slot of a cassette.
Using the 4-way button, select the number of wafer type to adjust or register from the list of wafer
type numbers displayed on the liquid crystal panel, and then press the [Start] button.
(Registration is done for each wafer diameter. Registration for each wafer thickness is not
available.)
Mapping is performed and the [Wafer No.] button for a slot in which there is a wafer blinks.
Press the [Wafer No.] button to specify the slot into which the wafer to be adjusted has been
inserted. The [Wafer No.] button for the selected slot stops blinking and stays lit.
Press the [Start] button.
The selected wafer is loaded from the cassette.
Adjust the orientation flat and notch positions.
Data saved in the internal memory is displayed on the liquid crystal panel.
<CW/CCW 00>
In the case of the AL120-6, data saved for each wafer size is displayed.
150 Data: <CW/CCW 00>
125 Data: <CW/CCW 00>
100 Data: <CW/CCW 00>
Correct the orientation flat and notch alignment position. Save the correction data in the internal
memory.
Use the 4-way button to correct the position.
4-way button [RIGHT]: Clockwise
4-way button [LEFT]: Counterclockwise
One pulse: About 0.1 degree
Register the correction value.
[M1]: Register <Save>
Press the [Start] button to repeat steps
to
.
•
If you do not press [M1] button but press the [Quit] button instead, the wafer is unloaded into the
cassette without saving the data.
•
Use the [Wafer alignment] control for adjusting the orientation flat positions.
No. 16
L-arm
rotation
origin
sensor
position
check
<L-arm rotation origin sensor check>
Do not continue the operation for longer than 5 minutes. Wait
for longer than one minute before restarting the operation.
This program can be used to check the back-side arm rotation origin sensor.
Confirm that there is nothing interfering with the arm.
Press the [Start] button.
The sensor detection state can be checked by the step-operation of the L-arm rotation motor.
•
Specify the motor operation using the menu buttons on the operation panel display and the 4-way
button.
4-way button [UP]: Rotate forward by 30 degrees <Forward 30>
4-way button [DOWN]
: Rotate backward by 30 degrees <Backward 30>
[M1]: Initialize the L-arm <L rotation initialize>
[M2]: Switch between excitation ON and OFF <Current ON/OFF>
[M3]: Rotate by 90 degrees <Forward 90>
Содержание AL120-6Series
Страница 2: ...This page intentionally left blank ...
Страница 9: ...Operation Maintenance Manual Introduction Safety Precautions i 7 Page AL120 86 Series Unit mm ...
Страница 16: ...Introduction Conformity Standards Operation Maintenance Manual i 14 Page ...
Страница 17: ...Operation Maintenance Manual Introduction Conformity Standards i 15 Page ...
Страница 18: ...Introduction Conformity Standards Operation Maintenance Manual i 16 Page This page intentionally left blank ...
Страница 20: ...Maintenance Manual Table of Contents C 2 This page intentionally left blank Page ...
Страница 56: ...Test Programs Maintenance Manual 3 26 Page This page intentionally left blank ...
Страница 64: ...Replacement of Consumables Maintenance Manual 4 8 Page This page intentionally left blank ...
Страница 65: ...This page intentionally left blank ...