Maintenance Manual
Test Programs
3-7
Page
Test No./
Test Name
Function Outline
No. 8
Vacuum
switch check
<Vacuum switch check>
This program can be used to turn each vacuum electromagnetic valve ON/OFF and check the ON/OFF
state of the corresponding vacuum switch.
Press the [Start] button. If the loader has not been initialized, initialization starts.
Select the electromagnetic valve to turn ON/OFF by using the Wafer No. selector buttons.
The arm height is changed each time the menu button on the liquid crystal panel is pressed.
Select a menu button ([M1] or [M2]) and press the [Start] button to being operation.
[M1]: Change the up/down position of the A-arm <A-arm change position>
[M2]: Change the L-arm position <L-arm change position>
•
Showing the vacuum switch ON/OFF state <Switch display>
The ON/OFF state of the vacuum switch that corresponds to the selected electromagnetic valve is
indicated on the Wafer No. selector button.
When the vacuum switch is ON, the LED on the Wafer No. selector button lights up.
[No. 1]: A-arm #1 <A1>
[No. 2]: A-arm #2 <A2>
[No. 3]: Center table <M>
[No. 4]: Stage <S>
[No. 5]: L-arm <L>
Turning the electromagnetic valve ON/OFF <Valve switching>
When the selected electromagnetic valve is ON, the LED on the Wafer No. selector button lights up.
[No. 11]: A-arm #1 <A1>
[No. 12]: A-arm #2 <A2>
[No. 13]: Center table <M>
[No. 14]: Stage <S>
[No. 15]: L-arm <L>
Turning the vacuum switch buzzer ON/OFF <buzzer switching>
The buzzer keeps sounding as long as the LED on the Wafer No. selector button is lit and the vacuum
switch is ON.
[No. 21]: A-arm #1 <A1>
[No. 22]: A-arm #2 <A2>
[No. 23]: Center table <M>
[No. 24]: Stage <S>
[No. 25]: L-arm <L>
•
When the [Quit] button is pressed,
t
he arms return to their initial positions and the loader stops the
operation.
No. 9
Stage lock
check
<Stage lock movement check>
Do not continue the operation for longer than 5 minutes. Wait
for longer than one minute before restarting the operation.
This program can be used to check the operation of the optional AL120-SLK when it is installed.
The stage lock is turned ON/OFF each time the [Start] button is pressed.
Содержание AL120-6Series
Страница 2: ...This page intentionally left blank ...
Страница 9: ...Operation Maintenance Manual Introduction Safety Precautions i 7 Page AL120 86 Series Unit mm ...
Страница 16: ...Introduction Conformity Standards Operation Maintenance Manual i 14 Page ...
Страница 17: ...Operation Maintenance Manual Introduction Conformity Standards i 15 Page ...
Страница 18: ...Introduction Conformity Standards Operation Maintenance Manual i 16 Page This page intentionally left blank ...
Страница 20: ...Maintenance Manual Table of Contents C 2 This page intentionally left blank Page ...
Страница 56: ...Test Programs Maintenance Manual 3 26 Page This page intentionally left blank ...
Страница 64: ...Replacement of Consumables Maintenance Manual 4 8 Page This page intentionally left blank ...
Страница 65: ...This page intentionally left blank ...