Test Programs
Maintenance Manual
3-12
Page
Test No./
Test Name
Function Outline
[M3]: Manual input of mapping parameters <Input parameter>
This program can be used to modify mapping parameters.
Using the 4-way button, select the number of the wafer type to modify from the list of wafer type
numbers displayed on the liquid crystal panel, and then press the [Start] button.
Parameter setting items are displayed on the liquid crystal panel.
Select the parameter to change with the 4-way button.
[M1]: Switching between mapping sensors 1, 2, and 3
[M2]: Save <Save>
[M3]: Delete<Back space>
[M4]: Terminate display <Exit>
[No.1 to No.9]: Input numbers 1 to 9. [No.10]: Input 0.
[No.21]: Input -. (To be used only for the offset start position)
4-way buttons [RIGHT] and [LEFT]: Move the cursor.
4-way buttons [UP] and [DOWN]: Move from one item to another.
Settable parameters
Item ...................................................Set value ............... Default
•
Number of cassette slots
<Slot>................................................:25/26 .................... 25
•
Slot pitch
<Pitch> ..............................................:4.760/6.350 .......... 150mm=4760/200mm=6350
•
Upper limit of wafer position error
<Upper> ..........................................:10 to 3000
•
Lower limit of wafer position error
<Lower> ..........................................:10 to 3000
•
Upper-limit value of wafer thickness
<Thick Upper>...................................:90 to 5000
•
Lower-limit value of wafer thickness
<Thick Lower>...................................:90 to 400
•
Start position
<Start Position>................................. ............................... 150mm=38500, 200mm=48500
Default
Select an item using the 4-way buttons and input a value using the wafer No. buttons.
To register the modified values, press [M2]: Save <Save>.
To terminate the program without modification, press [M4]: Terminate display <Exit>.
S1
S2
S3
AL120-86 Series
200mm
725um-400um
Upper 800 / Lower 800
Thick Upper 5000 / Thick Lower 400
Upper 800 / Lower 800
Thick Upper 5000 / Thick Lower 400
Upper 800 / Lower 800
Thick Upper 5000 / Thick Lower 400
200mm
400um-180um
Upper 800 / Lower 800
Thick Upper 5000 / Thick Lower 180
Upper 800 / Lower 800
Thick Upper 4000 / Thick Lower 180
Upper 800 / Lower 800
Thick Upper 4000 / Thick Lower 180
200mm
180um-90um
Upper 2000 / Lower 2000
Thick Upper 2000 / Thick Lower 90
Upper 1000 / Lower 1000
Thick Upper 5000 / Thick Lower 90
Upper 1000 / Lower 1000
Thick Upper 5000 / Thick Lower 90
150mm
675-400
Upper 600 / Lower 600
Thick Upper 4000 / Thick Lower 400
Upper 600 / Lower 600
Thick Upper 4000 / Thick Lower 400
Upper 600 / Lower 600
Thick Upper 4000 / Thick Lower 400
150mm
400um-150um
Upper 600 / Lower 600
Thick Upper 4000 / Thick Lower 150
Upper 600 / Lower 600
Thick Upper 4000 / Thick Lower 150
Upper 600 / Lower 600
Thick Upper 4000 / Thick Lower 150
AL120-6 Series
675um-400um
Upper 550 / Lower 550
Thick Upper 4000 / Thick Lower 400
400um-150um
Upper 550 / Lower 550
Thick Upper 4000 / Thick Lower 150
Содержание AL120-6Series
Страница 2: ...This page intentionally left blank ...
Страница 9: ...Operation Maintenance Manual Introduction Safety Precautions i 7 Page AL120 86 Series Unit mm ...
Страница 16: ...Introduction Conformity Standards Operation Maintenance Manual i 14 Page ...
Страница 17: ...Operation Maintenance Manual Introduction Conformity Standards i 15 Page ...
Страница 18: ...Introduction Conformity Standards Operation Maintenance Manual i 16 Page This page intentionally left blank ...
Страница 20: ...Maintenance Manual Table of Contents C 2 This page intentionally left blank Page ...
Страница 56: ...Test Programs Maintenance Manual 3 26 Page This page intentionally left blank ...
Страница 64: ...Replacement of Consumables Maintenance Manual 4 8 Page This page intentionally left blank ...
Страница 65: ...This page intentionally left blank ...