General settings
«TECHNICIAN MENU»
«SETTINGS» :
From this menu we can adjust all the general settings of the panel.
The first 3 options are described on the "Master user Menu" section
of the manual (Page 10).
«ENTRANCE TIME». That is the delay between a device (trap, ra-
dar etc.) triggering and an alarm event. This option is valid only for
zones that have been programmed as zones with delay. By pressing
" *
" a new screen appears and the current entrance delay is
shown (30) in seconds. Enter the new time (05-99, 2 digits are man-
datory) i.e. 0 and 9 for 9 seconds. The system stores the value and
returns to the menu
«SETTINGS».
«EXIT TIME». That is the time from when the arming password is
entered until the actual arming of the system. Pressing " *
" reveals
a new screen where the current exit time is shown. By default it is 45
seconds. We enter the new required exit time with 2 digit numbers
(00-99, 2 digits are mandatory) i.e. 6 and 0 for 60 seconds. The sys-
tem stores the value and returns to the menu
«SETTINGS».
«ALARM TIME». It is the time that the siren will stay active. This
time counts from the instance that all activation devices have
stopped activating the panel. Select 1 or 2 minutes. The system
stores the value and returns to the menu
«SETTINGS».
«EXTRA EXIT TIME». It is the extra time that is added to the "EXIT TIME". It is used when a user
arms the panel with a
«SET WITH DELAY EXTRA» code or the zone is declared as "ZONE NEXT
DELAY".
«SECTIONS EXIT TIME». With this selection we define if sections A, B, C have an arming delay. We
must reply YES or NO for each subsection.
«ENTRANCE DELAY BEEPS». A user can select YES if he wants the built-in buzzer to sound during
the entry countdown.
«EXIT DELAY BEEPS» A user can select YES if he wants the built-in buzzer to sound during the exit
countdown.
«BEEP PARTIALLY ARMED.» Select if the built-in buzzer will sound during the exit time in case of a
partial arming of the system (section arming
Α, Β or C).
«BEEP PARTIALLY ARMED» Select if the system can be armed without a password, with the use of
the keys A. B. C. ABC. The selection only affects the arming, for the disarming a password is always
required.
«ARM WITHOUT CODE». Indicates that the system can be armed just by pressing A, B, C, ABC. The
default selection is "YES".
«ARMED SYS INDICATORS». We have 2 selections «OFF» or «ON». The default selection is "ON".
When the option is enabled, the LED indicators are lit when the panel is armed. The indicators are
always lit when the panel is disarmed.
This option is not valid on wireless keyboard BS-477.
«IDLE BACKLIGHT MODE». This option affects the illumination of the display and the keypads during
the idle state of the system. The idle state is the state where there is not alarm and no key has been
pressed for 30 seconds. We have 3 options. ALWAYS OFF, ONLY WHEN DISARMED which means
______SETTINGS______
DAY OF WEEK SETTING
DATE SETTING
TIME SETTING
ENTRANCE TIME
EXIT TIME
ALARM TIME
EXTRA EXIT TIME
SECTIONS EXIT TIME
ENTRANCE DELAY BEEPS
EXIT DELAY BEEPS
BEEP PARTIALLY ARMED
ARM WITHOUT CODE
ARMED SYS INDICATORS
IDLE BACKLIGHT MODE
BUTTON PANIC
RECORD OUTPUTS EVENT
AUTOMATIC BYPASS
REMOTECONTROL ACTION
ANNUAL CHECK WARNING