1. During the above procedure, do not attempt to add another device into the network (i.e. siren,
magnetic contact, etc.) other than the keypad. If you attempt to add another device during the
wireless keypad detection process, the panel will ignore it.
2. The keypad detection process has a 1-minute timeout period, once the LD4 starts blinking. If
no keypad is inserted within 1 minute, LD4 will go out. To start the procedure again, the BT1
button must be pressed once again.
3. When the keypad is successfully entered, the zone 25 to which it is entered will be deactivated
(OFF). To switch it on, go to the technician's zone menu. This happens because the tamper is
not pressed, so the panel will send an alarm command. As a result, if a wired siren is con-
nected to it, it will start to sound.
4. If only a wireless keyboard is installed initially, then if a wired keyboard is connected later, the
second one will not communicate with the panel, therefore a keypad detection must be done
to start the panel communicating with the keyboard line.
5. The keyboard installation from the BS-479 extension as soon as it detects the keyboard will
erase all wireless zones and will insert the new keyboard into zone 25.
Wireless devices deletion
A) Deleting ALL wireless zones
From the main screen of the keyboard press
" *
"
and then select "MASTER OR TECH MENU ". By
typing the TECHNICIAN code we enter the technician menu. By pressing the "
8" button, on the se-
cond page of the menu we select the menu "WIRELESS NETWORK". We go down with the "
8" but-
ton and select "DELETE ALL ZONES". After a few seconds, we return in the wireless menu. Wireless
devices will leave the network after a maximum of 2.5 minutes.
NOTE:
If a wireless keyboard sends a command to delete its own zone, then after confirming the ac-
tion, exit the technician's menu and let it go out. Once it re-activated, in the screen will be displayed a
communication error message with the panel indicating that its zone is now erased.
B) Deleting individual zones
From the main screen of the keyboard press
" *
"
and then select "MASTER OR TECH MENU ". By
typing the TECHNICIAN code we enter the technician menu. By pressing the "
8" button, on the se-
cond page of the menu we select the menu "WIRELESS NETWORK". We go down with the "
8" but-
ton and select "DELETE SINGLE ZONE". We type the zone number that we want to delete and after a
few seconds we see the corresponding deletion success message on the keyboard screen. The de-
vice that was found in this zone exits the network after a maximum of 2.5 minutes.
NOTE:
If a wireless keyboard sends a command to delete its own zone, then after confirming the ac-
tion, exit the technician's menu and let it go out. Once it re-activated, in the screen will be displayed a
communication error message with the panel indicating that its zone is now erased.
C) Deleting devices manually
The following method of deleting a wireless device is recommended only if the wireless zone exten-
sion card (BS-479) needs to be changed.
The device must not have its battery. By pressing the tamper spring and holding it down, place the
battery. After about 3 seconds, the device red LED lights up and remains on for 10 seconds. Once it