7
921468007_09_010
Selecting
«WIRED ZONE CONDITION»:
In the following window we can test the good operation of the zones
and the devices connected to them. For examples, if a magnetic
contact of a window is connected to zone 4 and the window opens
then the message of the display from
«ALL ZONES OK» will be
erased and the indication 04 will start blinking. As soon as the win-
dow closes, the screen will display the previous message
«ALL
ZONES OK
». With this method we can test the good operation of
all the detectors and magnetic contacts.
The same applies to
«WLESS ZONE CONDITION», except the fact that the menu is dedicated to
wireless zones.
By pressing
«LAST ALARMS» we can view the alarms that were triggered during the last arming of
the system. The display will be like the one below:
This means that an alarm was triggered for zone 8 which is a
TAMPER zone (24 hour operation). The alarm was issued on 12:20
on 07 March 2012 and that is the first of 3 events.
Using the up and down arrows (keys 2 and 8) we can view all the
registered alarm events.
The
«LAST ALARMS» line is visible if an alarm has been triggered
at least once.
By selecting
«ALL EVENTS» we can see all events that have happened and are stored in the panel's
internal memory:
This means that an error event was triggered for Zone1 at 12:20 on
March 07, 2012. It also informs us this is the 70
th
event of a total of
70 events. With the up and down arrow keys (2 and 8) we can see
all the registered events.
The event memory has a capacity of 250 events and once filled the
new event will erase the oldest. The events that are registered are
errors, alarms, user and technician menu access as well as the
arming and disarming of the system. The main user and the techni-
cian can both erase the events memory using there respective
menus.
«MANUAL OUTPUTS CHECK»:
With "
2" and "
8" keys we can select the required option and by
pressing " *
" we can see or we can change the state of the output
Ρ1, Ρ2, Ρ3, RELAY.
Warning.
In order for an output to be able to change state from this
selection it must be programmed as
«ON-OFF MANUAL». When an
output changes state, the device connected to it is activated. A
manual change of the output sets the output to a permanent condi-
tion which can only change by manually changing the output again.
It is suggested to use this selection with caution and only if we want
to manually control a connected device.
TAMPER
ZONE 08
ΖΟΝΕ 8
07/03/12 12:20
001/003
ERROR
ZONE 01
ΖΟΝΕ 1
07/03/12 12:20
070/070
_MANUAL OUTPUTS CHECK _
CHANGE OUTPUT
OUTPUTS STATUS
WIRED ZONE CONDITION
ALL ZONES OK