18
921468007_09_010
Siren connections
For connecting the autonomous siren type BS-413 up-to 7 cables are required.
On the terminals (+)
και (-) connect the voltage (AS), (-) which charges the siren.
When we supply the (ST) with 12V the siren and the beacon are activated. Connect (ST) to the P1
contact of the panel which is programmed to provide 12V during an alarm and 0V during the idle state.
When the (SE) terminal is connected to (-) it prohibits the siren to operate. This cable is connected to
a (-) terminal of the panel during the installation procedure or any other time that the cover of the siren
must be removed (i.e. during a battery change). In normal operation the cable must be removed from
the (-) terminal of the panel.
When the (FL) terminal is supplied with 12V the beacon is activated. If it is connected to the terminal
P3 of the panel then the beacon will flash once for 2 seconds when the panel is armed and three times
(0.5 second duration) when the panel is disarmed.
The contacts (
Τ1) and (Τ2) are the TAMPER contacts of the siren which are connected to a respective
zone on the panel which by default is zone 8 (TAMPER zone).
To connect an internal siren BS-441, two cables are required. Connect the (ES) and (-) of the panel to
the respective (+) and (-) of the siren.
Each panel can accept up-to 2 external autonomous and 1 internal siren.