34
921468007_09_010
ATTENTION!. The above screen changes if the user uses a wireless keyboard (BS-477). The differ-
ence is that letter E is inserted by pressing "
*
" and letter F by pressing " #. If the user does not type a
digit within 10 seconds, the keypad returns to the "WIRELESS NETWORK" menu.
If there is another device in place of the zone we select, the panel will display the failed assignment
message. In this case, the existing zone must be deleted and then re-assigned.
«NETWORK INSTALLATION»
In order to have a fully operational wireless alarm network, all the devices must be assigned into wire-
less zones. This is done through "Network Installation", a procedure that is covered in detail on the
next page of this manual.
«DELETE SINGLE ZONE»
We can delete a single wireless zone. Acceptable zone numbers are 25 - 56. Once this action is com-
pleted, it is suggested that you press the device tamper so that the deletion can be validated instantly.
«DELETE ALL ZONES»
Through that choice, the user can delete all wireless zones of the system.
«RF COMM SUPERVISION»
Enables or disables wireless communication supervision. When the option is turned on, the panel
monitors the time at which the devices send a signal to it. If a device does not send a signal for 2
hours, then a fault message appears on the screen. The factory default setting is set to ON.
«WIRELESS TAMPERS»
This feature allows us to monitor in real time whether the switch of any wireless device installed on the
network is pressed or not. The numbers which displayed, are the wireless zones whose tamper is ac-
tive (not pressed). When wireless keypad is used, its screen is refreshed every 8 sec.. Thus there
might be an 8-second delay (maximum) from the switching state of the device until this event on key-
pad’s screen to be displayed.
«WIRELESS SENSORS»
This feature allows us to monitor in real time whether the sensor of a wireless device that is installed
on the network is turned on or off. The numbers displayed are the wireless zones that give a sensor
activation signal. When wireless keypad is used, its screen is refreshed every 8 sec.. Thus there might
be an 8-
second delay (maximum) from the switching state of the device until this event on keypad’s
screen to be displayed.
«SIGNAL STRENGTH»
This option is only available on the
BS-477
wireless keyboard and allows us to monitor the strength of
the wireless signal according to the keyboard position. The display shows the signal power in 1 - 4
range and as RSSI (value in brackets). The bottom dashes are there to show us the communication
existence between the keyboard and the table. If they are blinking it means the device is on range and
receiving the panel's commands.
«SIREN LED SETTING»
Available options in this mode are YES and NO. If you select "YES", the siren beacon will flash 3 times
when the system is armed. Also, when disarming the system, it will light up one time. If you select
"NO", the siren beacon will not light up during both the arming and disarming of the system.
«RF MASTER INFO»