An alarm system is not recommended to have more than 2 wireless keyboards installed. No more than 
one keypad should be used when changes are made to the system.  

It is forbidden to send settings or to type codes from 2 keypads at the same time. 

The arming keys are activated after pressing them for 2 seconds. 

The panic key on the wireless keyboard is "# ESC" and is activated by pressing  it for 5 seconds. This 
specific  key  can  be  pressed  even  if  the  keys  are  locked.  In  such  a  case  the  panic  key  unlocks  the 
whole keypad. 

BS-477 MENU 

It is the same as of BS-466/A menu, but with some minor differences. Most importantly, when entering 
a menu, the current active setting is not illuminated, as in BS-466/A. Instead of that, the first setting is 
always selected.  

"ARMED SYS INDICATORS" and "IDLE BACKLIGHT MODE" menu options do not affect BS-477 and  
are intended for use with BS-466/A only. 

Inside "WIRELESS NETWORK" menu an extra line "SIGNAL STRENGTH" exists in BS-477. 

SIGNAL STRENGTH MENU 

"TECHNICIAN MENU" 

 "WIRELESS NETWORK" 

 "SIGNAL STRENGTH".  

The  user  sees  the  current  signal  strength  value  on  the  screen.  This  value  is  updated  every  few  se-
conds. When refreshed, the display shows "- - - -" a while. Values above 30 means good signal, 20 to 
30 average signal, and below 20 means "low signal". Below this value, communication may exist, but 
there will be an increased number of lost packets. It is not recommended to install a keypad to a posi-
tion that the indication is less than 20. For a safe conclusion about the signal at one point, the keypad 
should take measurements at this point for 10-15 seconds in order to renew display 5-6 times. Thus 
the user will be able to draw a conclusion about the mean value of signal strength at this point. 

 

3.5. 

Resetting to factory default passwords 

 
The main board of the panel contains 2 pins with the marking CODE RESET. Through these pins we 
can reset the passwords to the factory defaults by following the procedure below: 
 

1.  Connect the cable SERVICE of the siren to a (-) on the panel. 
2.  Isolate the mains power supply and disconnect the battery. 
3.  Link the pins CODE RESET by placing the jumper at both pins. 
4.  Connect the mains power supply and the battery. 
5.  Remove the jumper when the display of the keyboard lights. 

 

After  this  procedure  the  main  master  code  is  1234  and  the  technician  code  is  9999  and  all  the  user 
codes are empty. 

3.6. 

Programming via computer 

The programming of the panel can be done easily by using the special computer software PC-468 that 
is  provided  free  by  Olympia  Electronics.  A  simple  USB  to mini-USB  cable  (BS-466/A  keyboard)  or  a  
USB to Type-B cable (connection to the panel's board) and a CD with the latest version of the program 
is required. It is not recommended to connect the panel or keypad to the computer via a USB hub. 

Содержание BS-468/A

Страница 1: ...BURGLAR ALARM PANEL BS 468 A...

Страница 2: ...uts programming 27 System general parameters programming 28 BS 464 GSM telephone dialer programming 31 Wireless Network 33 Factory Menu 35 3 4 Wireless Zones Functions 35 Wireless Zones Extension Boar...

Страница 3: ...aken to load data from the file is as follows 55 Save settings to a file 55 Send settings to the panel 55 Offline Connection 56 New 56 Panel s Firmware Update 57 4 I OLYMPIA APPLICATIO 58 5 Technical...

Страница 4: ...has port for connecting an YET 205B 630 remote control receiv er and an automatic telephone dialler On the telephone dialler port you can connect a BS 465 wired PSTN telephone dialer or a BS 464 wirel...

Страница 5: ...simply pressing the ABC key if during the programming the option ARM WITHOUT CODE has been se lected The disarming of the system can be done by using the master code or one of the user code that have...

Страница 6: ...s are disabled will not be armed during the next arming of the system For example if we enter 04 and then immediately 07 this means that the next time the system is armed zones 4 and 7 will be disable...

Страница 7: ...t have happened and are stored in the panel s internal memory This means that an error event was triggered for Zone1 at 12 20 on March 07 2012 It also informs us this is the 70 th event of a total of...

Страница 8: ...ion that can be changed by the user By typing the master code the next display shows With the EVENTS selection we can see all events or delete the events in memory If we choose to erase the events mem...

Страница 9: ...that we want to delete After that the system deletes the password If we want to change the main password from the CODES menu select CHANGE MAIN PASS WORD By pressing the key we see After entering the...

Страница 10: ...By default the selection is set to 40 The specific option is NOT available on BS 477 wireless keyboard With the selection IDLE BACKLIGHT MODE we can set the way the display is illuminating when activ...

Страница 11: ...number The following screen ap pears If the CHANGE TIMER is selected it means that the timer is active If the DELETE TIMER is highlighted then this means that the timer is inactive The inactive timer...

Страница 12: ...nd do not exist anymore If for example an SMS could not be delivered in a past time and the user press RESET the specific warning will be deleted But if a battery is disconnected by press ing RESET th...

Страница 13: ...entrance area On zones 3 and 4 the rest of the radars and on zones 5 to 7 the magnetic contacts that we require to give an immediate alarm Finally on zone 8 con nect the TAMPER of the external siren W...

Страница 14: ...of the ground floor radar detectors and if we arm sections ABC we have full operation of the system 3 Zone 1 Zone with delay section With bell sound Zone 2 Zone with delay section Zone 3 Zone without...

Страница 15: ...n B Zone 16 Zone without delay section B Zone 17 keyboard 1 Zone with delay section This configuration is suitable for a large store with sections A B present 6 Zone 1 Zone with delay section Zone 2 Z...

Страница 16: ...rminals and a small alignment vial that is used to correctly mount the base After connecting the cables the main body is fastened to the base A screw on the bottom side does not permit accidental remo...

Страница 17: ...one after the other No terminal should contain 3 cables or more The jump ers of the terminal resistors must be placed only on the two outermost devices On all the other devic es is should be removed...

Страница 18: ...at the cover of the siren must be removed i e during a battery change In normal operation the cable must be removed from the terminal of the panel When the FL terminal is supplied with 12V the beacon...

Страница 19: ...to the respective terminals of all the detectors The other 2 cables connect in series the contacts RELAY NC of all the detectors of the zone and the resistors found on the terminals of the panel The d...

Страница 20: ...2 menus EVENTS NOTIFICATION of the ARC Alarm Receiving Center of the PSTN and the GSM When a value is entered i e entry time and after the last digit is entered the value is stored auto matically wit...

Страница 21: ...ician that installs the panel It is noted that in BS 466 A in Technician Menu if no key is pressed for 2 hours the keypad returns to the main screen exiting the Technician Menu In BS 477 this time is...

Страница 22: ...Making this selection and pressing we must select the section that is affected by the password We can select A B C or ABC SET WITH DELAY EXTRA The password arms only does not disarm the panel but wit...

Страница 23: ...define if sections A B C have an arming delay We must reply YES or NO for each subsection ENTRANCE DELAY BEEPS A user can select YES if he wants the built in buzzer to sound during the entry countdow...

Страница 24: ...request a bypass confirmation for each active zone REMOTECONTROL ACTION We select the operation mode of the remote control if available The available actions are ARM DISARM PANIC ALL FUNCTIONS and DEA...

Страница 25: ...cian can adjust the parameters of the zones These functions apply for both wired and wireless zones By selecting it we can enter the desired zone number 01 56 After inserting the zone s number the nam...

Страница 26: ...it will arm the whole system or a section of it It can be used to arm the panel through some other system such as a BMS or fire alarm system The zone must be connected with a normally closed contact...

Страница 27: ...ble For the last three settings the panel will automatically select the correct setting If no special settings are required then it is good practice not to alter them Wired zones status TECHNICIAN MEN...

Страница 28: ...esent time System general parameters programming TECHNICIAN MENU SYSTEM DEVICE ADDRESS By default each keyboard BS 466 A is assigned by address 2 If we only have one keyboard there is no reason to cha...

Страница 29: ...numbers local or international Using this menu we select the number of the telephone that we want to al ter Select from 1 to 6 After selecting the number of the phone that we want to alter the follow...

Страница 30: ...Center is activated or deactivated ARC PHONE NUMBER We can enter the telephone number of the ARC PANEL ID 0 9 B F we can enter the ID of the alarm panel using the numbers 0 to 9 and the letters from...

Страница 31: ...nt to alter the fol lowing screen is shown At this point we can select if during the selected events the GSM will call and send an SMS to the tel ephone number will only call or will only send an SMS...

Страница 32: ...one calls even if the calling telephone number has been programmed to send remote commands As of the second option 15 seconds is not an strict value 1 second differences can be observed depending each...

Страница 33: ...477 d ID This is the unique address each device has e RSSI 4 The devices signal strength appears on a scale from 1 to 4 ASSIGN ZONE Normally on Network Installation every device that is recognized is...

Страница 34: ...ime whether the switch of any wireless device installed on the network is pressed or not The numbers which displayed are the wireless zones whose tamper is ac tive not pressed When wireless keypad is...

Страница 35: ...ow there are all the necessary steps required to install add wireless devices to the BS 468 A bur glar system The specific procedure takes place by choosing NETWORK INSTALLATION and can be started onl...

Страница 36: ...hen all of the above steps have been completed the rest of the wireless network settings can be executed normally by the BS 477 Wireless network installation without keyboard and PC The procedure is s...

Страница 37: ...n with the 8 but ton and select DELETE ALL ZONES After a few seconds we return in the wireless menu Wireless devices will leave the network after a maximum of 2 5 minutes NOTE If a wireless keyboard s...

Страница 38: ...performing Network Installation For example it is impossible to connect devices on the panel from the house next door that are already installed on another BS 468 A panel Also only Olympia Electronic...

Страница 39: ...so a terminal for connecting an external magnetic contact which when not in use must be short circuited WIRELESS MAGNETIC CONTACT BS 471 Wireless Magnetic Contact features 2 DIP switches DS1 and a Tam...

Страница 40: ...value communication may exist but there will be an increased number of lost packets It is not recommended to install a keypad to a posi tion that the indication is less than 20 For a safe conclusion a...

Страница 41: ...rly If we accidently open the PC program before the drivers installation is finished and the communication indicator is red instead of green see first picture on the next page we must close the PC pro...

Страница 42: ...e current attached de vices of the panel will appear While the panel tries to enumerate the connected system peripherals the OK button is not active The picture bellow shows an example of a system tha...

Страница 43: ...ing on the code the access level is different The factory setting for the technician code is 9 9 9 9 and for master code 1 2 3 4 From now and on we can change or view all the settings of the panel suc...

Страница 44: ...such as Zones information passwords events timers and outputs Because this function is time consuming if we need to take information for specific features of the panel it is better to load the data fr...

Страница 45: ...he panel If we want to make the changes permanent we have to press Send A window showing the send progress appears and it will disappear when the settings have been sent After that the entry time fiel...

Страница 46: ...46 921468007_09_010 While being in Technician mode the user can adjust the function of each zone If Master mode is enabled see picture below the user can only change the name of the zone...

Страница 47: ...e name of the Code see the picture below The Code name is not being sent to the panel It is saved in a file and can help the alarm installer When we change the password we are asked to type it 2 times...

Страница 48: ...columns that appear are A A The event number Date and time of the event Category It may be Alarm Fault General Normal Bypass Warning etc Source Where the event came from It can be the Panel Keypad Zon...

Страница 49: ...e file with the settings of the panel We can save them in a separate file by pressing the button Save located in the down right corner as shown in the picture below The Open button is used to load an...

Страница 50: ...Sector A every Monday at 7 00 while Timer 4 arms the system every Wednesday at 17 00 Outputs Window In Outputs window we can see and set the panel s outputs functions Their operation is described in a...

Страница 51: ...installation Added devices appear in the white text box below the Network Setup section Zones deletion With Delete all wireless zones button we can delete all the available wireless zones that exist i...

Страница 52: ...rsion These fields are read only Receive and set RF supervisor and Wireless Siren LED By pressing the Receive button we can read the data from the panel By pressing the Send button we can send these d...

Страница 53: ...rresponding settings The number must be active In the area below the number there are cells where we can define the actions that will be performed when events are triggered by the panel These actions...

Страница 54: ...absence of AC power If the system is connected to a Alarm Receiving Center we can set or read the settings of this center Master and Technician user password modification In case we have gained TECHN...

Страница 55: ...nd or extensions 2 Load settings file 3 Press New and then Connect Save settings to a file By pressing the following button we can save our personal panel configuration ATTENTION In order to save all...

Страница 56: ...the indicator to the down left bottom of the above screen reveals the connection ab sense between the panel and the PC After we press the button New we see the following window We can choose whether...

Страница 57: ...in panel board and NOT on the keypad BS 466 A The user is asked if he agrees with the upgrade At this point the version in which the table will be upgraded is also mentioned For the latest version of...

Страница 58: ...58 921468007_09_010 4 I OLYMPIA APPLICATIO Olympia Electronics Alarm application is available for smart phones and tablets for Android or IOS You can download it at Google play or Apple store...

Страница 59: ...d when the alarm goes off Outputs P1 P2 P3 General outputs with a 13 8V 200mA rating These outputs are activated depending on the panel settings Relay Output Relay change over output NC C NO The volta...

Страница 60: ...ompanies each product This warranty ceases to exist if the buyer does not follow the technical instructions included in official documents given by Olympia Electronics or if the buyer modifies the goo...

Страница 61: ...password 1 2 3 4 ____________ Technician password 9 9 9 9 ____________ Users Passwords Password Owner Function Password Owner Function 01 26 02 27 03 28 04 29 05 30 06 31 07 32 08 33 09 34 10 35 11 3...

Страница 62: ...22 41 04 23 42 05 24 43 06 25 44 07 26 45 08 27 46 09 28 47 10 29 48 11 30 49 12 31 50 13 32 51 14 33 52 15 34 53 16 35 54 17 36 55 18 37 56 19 38 Various information Entry time ________ seconds Exit...

Отзывы: