Lubrication Work Center
24
Filling the Tank(s) (
See Figure 17 and Figure 18 for details)
STEP 4.
Remove dust cap from quick disconnect.
See Figure 17.
STEP 5.
Connect ¾” color-matching quick disconnects (Suction Hose & LWC frame).
See Figure 18.
STEP 6.
Put the operating valve handles for the tank in the “Fill” position (up and up).
STEP 7.
Press the START button above the corresponding Dispensing Faucet to begin loading the Bulk Tank.
STEP 8.
Monitor the Bulk Tank Fluid Level Gauge to avoid over filling of tank.
STEP 9.
When the tank is full, raise the suction tube vertically out of the oil drum and allow the pump to pull through any
residual oil remaining in thesuction hose assembly then press the STOP button above the Dispensing Faucet to
turn off the pump.
STEP 10.
Separate ¾” quick disconnects, replacing dust caps over each connector half. Then then store the suction hose
assembly for future use.
STEP 11.
Remove the Static Discharge Clip.
FIGURE 17: Remove Fill Port Inlet End Cap
FIGURE 18: Attach Suction Hose Assembly to Inlet
CAUTION!
Care must be taken when reeling cable back onto the reel.
DO NOT
let go of the
cable – walk it backtowards the reel, keeping tension on cable at all times.