Lubrication Work Center
12
Installation
CAUTION!
Personal Protective Equipment (“PPE”) should be worn when installing and operating this
system.
System Operating Pressure should NEVER exceed 300 PSI. System operating
pressures can be regulated by adjusting pump bypass relief valves located on pump
heads to suit specific lubricant viscosities and temperatures.
System SHOULD NOT be operated in a location with an ambient room temperature less
than 60°F/15°C Contact the manufacturer for more information relating to service in cold
environments.
STEP 1.
The system is delivered pre-assembled, packaged, and serialized. Each frame is assigned a dash number, after
the serial number. Serial numbers are all located on backside of each frame. These serial numbers also indicate
the respective pod/frame position from left to right, when viewed from the front side of the frames.
STEP 2.
Locate Pod-1 and remove and appropriately dispose of the freight packaging.
STEP 3.
Using a suitable hand pallet truck, position Pod-1 into its service position, ensuring that there is at least 36" of free
clear space at the rear and18"on side of the system. This will enable personnel to access the system for service
work.
See Figure 4.
FIGURE 4: Recommended Clearance