Страница 1: ...OSOM ABS Rev1 Advanced Bulk System IMPORTANT Please read this Owner s Manual carefully and thoroughly before installing and operating your Advanced Bulk System Please retain this Owner s Manual for f...

Страница 2: ...acement Procedures 35 Replacement Parts 36 Tank or Motor Replacement 38 Data Tables 39 Plumbing Schematic 40 FOR YOUR RECORDS Write the model and serial num bers here You can find them on the Serial M...

Страница 3: ...or injury FAILURE TO FOLLOW this caution will void your product warranty IMPORTANT This text will be used before text that has been designated as important to the proper installation operation or main...

Страница 4: ...HE CLOSED POSITION WHEN SERVICING THE SYSTEM ALWAYS ensure that the System Pressure Return Hoses discharging to the upper port on the rear face of each tank are never restricted or damaged THE BULK TA...

Страница 5: ...eld to be invalid or unenforceable for any reason such finding will not invalidate any other provision For products purchased in countries other than the United States please contact OS authorized rep...

Страница 6: ...kPod or Pod 1 in the event you have purchased more than one Pod Each Tank Pod can contain many different varieties of tanks including One 240 gallon tank Two 120 gallon tanks Four 65 gallon tanks show...

Страница 7: ...Advanced Bulk System 7 FIGURE 1 Electric Tank Pod Pod 1...

Страница 8: ...Lubrication Work Center 8 FIGURE 2 Pneumatic Tank Pod Pod 1...

Страница 9: ...f Pods for your order Follow written instructions to assemble and install prior to operating NOTE For this manual the Tank Pod s will each be shown with four 65 gallon Bulk Tanks POD 1 TANK POD POD 2...

Страница 10: ...ipped with a 100 ampere ground clamp and rubber covered bumper An instant acting lock and release provides operator convenience IMPORTANT CARE MUST BE TAKEN when reeling the cable back onto the reel D...

Страница 11: ...have been installed at the rear ofthe system positioned behind where the motors will be located Each power outlet should be equally spaced along the wall and be placed approximately 12 up from floor...

Страница 12: ...ce in cold environments STEP 1 The system is delivered pre assembled packaged and serialized Each frame is assigned a dash number after the serial number Serial numbers are all located on backside of...

Страница 13: ...eight packaging STEP 6 Using a suitable hand pallet truck position Pod 2 to the right of Pod 1 so that the spill transport pallets are square and flush next to one another See Figure 5 and Figure 6 ST...

Страница 14: ...ply by ordering an optional Spill Containment Connector Kit The kit can be installed in a few minutes and is easily disconnected if it becomes necessary to move frames See Figure 7 FIGURE 7 Spill Cont...

Страница 15: ...ert the float assembly into the tank e Screw the aluminum bushing into the tank port until tight and ensure the arrows on the flat side of the hex bushing are pointing toward the back wall of the tank...

Страница 16: ...is sitting flush on top of the small metal clip you may have to file off any burrs on the end of the rod to fit the magnet onto the rod STEP 13 Once the clip is installed with the magnet on top of it...

Страница 17: ...white elastic band from top of desiccant air breather Remove red plastic cap plug from bottom side of desiccant air breather Screw clockwise desiccant air breather onto male pipe fitting atop oil tank...

Страница 18: ...wrench to flats on the mainspring shaft rotating counter clockwise until the desired tensionis reached b If mainspring tension is too high it may be decreased by depressing the tension lock spring on...

Страница 19: ...ant grounding equipment as specified and installed by your authorized electricalpersonnel ELECTRICAL INSTALLATION For Pneumatic systems proceed to page 20 STEP 1 THE SYSTEM SHOULD BE GROUNDED BEFORE U...

Страница 20: ...ations before proceeding STEP 1 At the front of the system unscrew the plastic plug from the female NPT port on the inlet air valve See Figure 13 STEP 2 Fasten the desired coupler into the front femal...

Страница 21: ...oming out of the lines and fluids to dispense normally before continuing If air continues to come out of the hoses after the initial use there maybe a problem with a seal or a hose See the Troubleshoo...

Страница 22: ...ocate the Suction Hose Assembly Each tank will have its own individual Suction Hose Assembly See Figure 14 STEP 2 Place the tube end of the Suction Hose Assembly into the oil drum or container 55 gall...

Страница 23: ...ails STEP 3 Attach the Static Discharge Cable to the drum See Figure 16 FIGURE 16 Attach Static Discharge Cable CAUTION When filling Bulk Tanks from drums or barrels always ensure the Static Discharge...

Страница 24: ...of tank STEP 9 When the tank is full raise the suction tube vertically out of the oil drum and allow the pump to pull through any residual oil remaining in thesuction hose assembly then press the STO...

Страница 25: ...OWN right UP STEP 13 Press start button to run each filled Bulk Tank for the approximate times set out in the Re Circulation Kidney Loop Cycle Time Guide table in the Data Tablessection page 39 Dispen...

Страница 26: ...with theSystem provided the pump pressure bypass relief valves on each pump have first been set to suit the oil viscosity and ambient room temperature as the fluid will bypass back to the correspondin...

Страница 27: ...the desired location or place a container under the nozzle STEP 3 Put the nozzle in the required location ensuring it is secure STEP 4 Pull on the red trigger to dispense the fluid NOTE Due to the ai...

Страница 28: ...ystem is running or energized SEVERE injury or death may occur The Tank Isolation Valves located on the underside of each tank must be in the open position when operat ing the system and in the closed...

Страница 29: ...es set out in the Tank Re Circulation Kidney Loop Cycle Time Guide in theData Tables Section page 39 Put the valves in the Re Circulate configuration left DOWN right UP Run each filled Bulk Tank for s...

Страница 30: ...sion on Static Discharge Reel If additional tension is needed apply a wrench to the flats on the mainspring shaft rotating counterclockwise until the desired tension isreached If mainspring tension is...

Страница 31: ...ill pan at the bottom of the Pod STEP 7 Disconnect hoses on Spill Containment if Connector Kit is used Page 14 STEP 8 Repeat all steps until each pod is isolated similar to how it was delivered initia...

Страница 32: ...and float assembly with a lint free cloth to remove any excess fluid 3 Ensure all hinged joints and fittings are in good condition and moving freelyand reinstall 4 If the gauge is still not working co...

Страница 33: ...ispensing Faucet to remove dirt debris or clogs 9 Check the O ring on the Dispensing Faucet Replace if necessary The motor stops working 1 Have electrician check electrical enclosure to ensure power i...

Страница 34: ...bient room temperature where the system is installed should be in the range of 60 F 15 C TO 80 F 26 C For ambient temperatures below 60 F 15 C consult the manufacturer or your supplier for the supply...

Страница 35: ...n the open position when operating the system and in the closed position when servicing the system The major components of the system were designed to be replaceable Before attempting any repairs or r...

Страница 36: ...e is located at the top center of each tank It can be removed and replaced by screwing it on or off Direct Mount Overfill Alarm This is optional equipment signals if your tank is overfilling This is a...

Страница 37: ...ge Ball Knob 821006 Colored Ball Knob for Steel Faucet Shut Off Valve Purple Ball Knob 821007 Colored Ball Knob for Steel Faucet Shut Off Valve Red Ball Knob 821008 Colored Ball Knob for Steel Faucet...

Страница 38: ...tion Fastener Tool Size Dispensing Console Faucet Mounting Screws No 10 24 Cap Screws Hex Key 1 8 Dispensing Console Pressure Gauge Face Mounting Screws No 6 Cap Screws Hex Key 5 64 Dispensing Console...

Страница 39: ...2 42 42 70 70 70 65 91 91 91 91 91 152 152 152 120 168 168 168 168 168 280 280 280 240 336 336 336 336 336 560 560 560 TABLE 4 OILSAFE Bulk Oil Tank Capacities in Gallons STANDARD TANK SIZE APPROX BRI...

Страница 40: ...eturn 4 Return check valve 5 Fire protection valve with fusible link 6 3 4 Female quick disconnect 7 Suction 3 way ball valve 8 1HP 1200rpm motor 3gpm 11 4lpm 150psi 10 3bar pump or Pneumatic diaphrag...

Страница 41: ...or any customer service ordering requests or warranty issues please contact your authorized supplier or OilSafe You may contact OS as follows Telephone 972 771 1000 930 Whitmore Drive Fax 972 722 3252...

Страница 42: ...Lubrication Work Center 42 Notes...

Страница 43: ...Advanced Bulk System 43 Notes...

Страница 44: ...Lubrication Work Center 44 930 Whitmore Drive Rockwall TX USA 972 771 1000 sales oilsafe com www oilsafe com 2022 Whitmore...