Lubrication Work Center
6
Introduction
Thank you for purchasing an
OilSafe
®
Advanced Bulk System
. This System was designed to store and dispense bulk
lubricants in the workplace.The system was designed with quality in mind and is fully modular. The interchangeable series
of tanks, frames, pumps, filters, and storage modules have been customized for your application. The installation,
operation, and maintenance instructions in this document will provide you with all the information you will need for the
lifetime of your system.
The system was specially configured per your specification. It features up to four standard tank sizes mixed and matched
to your specifications, and color- coding to prevent cross-contamination and misapplication of fluids. Your system was
designed to store and dispense lubricants up to ISO 680 (if specifiedat the time of order).
Throughout this document, we will be referring to each individual frame set (that houses a set of tanks, motors, pumps,
spill pan, faucets etc.) as a “TankPod” (or “Pod-1” in the event you have purchased more than one Pod).
Each Tank Pod can contain many different varieties of tanks including:
• One - 240-gallon tank
• Two - 120-gallon tanks
• Four - 65-gallon tanks (shown in this manual)
• Four – 30-gallon tanks
Combinations of these tanks can be configured for
your system as desired, and number of Pods can be
purchased to accommodate number of tanks
required to meet your applications.
Each Dispensing Pod can contain up to four (4) Dispensing Faucets. The number of Dispensing Reels will
depend on the number of available positions not used by tanks. The maximum number of hose reels for each pod
can be determined by starting with the number 4 and subtracting the number of tanks on the system. i.e. if a
systems has 2 tanks, then 2 dispensing reels will fit on the frame (4-2=2). If more dispensing reels are
required, a Hose Reel Rack can be used to house additional dispensing reels.
See Figure 1 and Figure 2 on pages 7 and 8.
Please make sure operating valves are in “Recirculation” positions before start-up and at
shutdown of units. This provides the lowest amp draw and system pressure, ensuring the
safest conditions for operators during start-up and shutdown of the unit.
Содержание Advanced Bulk System
Страница 7: ...Advanced Bulk System 7 FIGURE 1 Electric Tank Pod Pod 1...
Страница 8: ...Lubrication Work Center 8 FIGURE 2 Pneumatic Tank Pod Pod 1...
Страница 42: ...Lubrication Work Center 42 Notes...