Advanced Bulk System
21
Initial Operation
IMPORTANT:
•
Follow these steps the very first time you use your system.
WARNING!
The Tank Isolation Valves (located on the underside of each tank) must be in the open position
whenoperating the system and in the closed position when servicing the system.
CAUTION!
Personal Protective Equipment (“PPE”) should be worn when installing and operating this system.
ALWAYSmonitor the system whenever the pump is running, or fluid is dispensing.
System Operating Pressure should NEVER exceed 300 PSI. System operating pressures can be
regulated by adjusting pump bypass relief valves located on pump heads to suit specific lubricant
viscosities and temperatures.
System SHOULD NOT be operated in a location with an ambient room temperature less than 60°F/15°C
Contact the manufacturer for more information relating to service in cold environments.
The first time the system is used there will be some air that has been trapped in the hoses. This is normal and will not affect
the system. Simply wait for theair to stop coming out of the lines and fluids to dispense normally before continuing. If air
continues to come out of the hoses after the initial use, there maybe a problem with a seal or a hose.
See the
Troubleshooting Section (page 33)
of this manual or contact your supplier for additional support. Ensure that the Tank
Isolation Valves located on the underside of each tank are in the open position before continuing.
Using the Operating Valve Handles & Modes of Operation
Each tank assembly has two operating valve handles located on the front of the Tank Pod. The position of these handles
will determine how your systemwill pump the fluid. There will be a placard on the front of the Tank Pod indicating which
position the handles will need to be in for each setting.
To fill the tank(s) – place both valves in the “UP” position, so the handle is parallel to the ground. To re-circulate the fluid in
the tank(s), turn the left-sidehandle (above the inlet valve) so it is perpendicular to the floor, and keep the right-side handle
parallel to the floor. To dispense the fluid in the tank(s) (normal operation), turn both handles to be perpendicular to the
floor.
OPERATING VALVE POSITIONS
FILL
RECIRCULATE
DISPENSE
Left – Up
Left – Down
Left – Down
Right –Up
Right – Up
Right –Down