Tools, Materials, and Personnel Requirements:
•
A minimum of two people is recommended to complete installation and setup.
•
Electrical hook-ups and installation should be completed by your authorized electrical personnel in accordance with
all local and federal laws andregulations.
•
A hand pallet truck is required to move each Pod into position.
•
1 - 1/2” wrench for connecting spill pallets.
•
3/4" wrench for system leveling/jacking bolts.
•
2 - 3/8" wrench to tighten Fluid Level Gauge.
•
Personal Protective Equipment (“PPE”) should be worn when installing and operating this system.
Determine Placement:
1.
The system should be installed indoors on a flat, level surface with sufficient load-bearing capacity to support the total
system weight.
See Table 5on page 38.
2.
Each mains supply electrical enclosure, and each motor requires a separate power outlet. See your specification
sheet (or system supply quotation) for electrical requirement details. Give consideration, to whether more than one
pump could be running at the same time, in which case it is recommended that each power outlet be wired with
independent circuits. CONSULT WITH AN AUTHORIZED AND TRAINED ELECTRICIAN.
3.
BEFORE beginning installation, determine where your system will be installed and ensure sufficient power outlets
have been installed at the rear of the system, positioned behind where the motors will be located. Each power outlet
should be equally spaced along the wall and be placed approximately 12" up from floor level.
4.
Pneumatically operated systems (in lieu of electrical) should be prepared with the same considerations, sizing
pneumatic lines and circuitry following OSHA safety guidelines.
IMPORTANT:
•
It is important to note the effect of the ambient temperature in which the system is placed for
operation. System room temperature should be in the range of 60°F (15°C) TO 80°F (26°C) with
optimum room temperature being 70°F (21°C). For ambient temperatures below 60°F (15°C)
consult the manufacturer or your supplier for the supply of electric blanket heaters for oil barrels,
pails, and bulk tanks to ensure stability of lubricant viscosity, condition, and system performance.
•
Temperatures less than (<60°F / 15°C) can result in lubricant viscosity increasing above the rated
ISO Code you specified at the time of order. Such adverse viscosity changes can cause higher
system operating pressures than those setat the factory.
•
System operating pressure should never exceed 300 PSI. Normal system operating pressure
should be less than 240 PSI. Operating pressures above 240 PSI will necessitate adjustment of
the pump pressure relief bypass valve located on the pump head.
•
Contact the manufacturer for more information prior to commissioning the system if the ambient
room temperature willever fall below 60°F (15°C).