Lubrication Work Center
26
Dispensing Mode (continued)
NOTE:
Due to air that has been trapped in the hoses during assembly, air will come out of the
faucet initially.
Keep the faucet in the open position until fluid is flowing at a steady pace.
CAUTION!
Do not wedge anything under the handle to force it to stay open.
NOTE:
Leaving the pump running against a closed Dispensing Faucet will not cause a pressure
problem with theSystem, provided the pump pressure bypass relief valves on each pump
have first been set to suit the oil viscosity and ambient room temperature, as the fluid will
bypass back to the corresponding Bulk Tank via the pump bypass pressure return hose.
Normal System operating pressure should be less than 240 PSI when pumping
against a closed faucet and should never exceed 300 PSI. Refer to the Trouble
Shooting section at the rear of this manual for the bypass valve pressure setting
procedure should your system operating pressure require adjustment. When the
system is running, it should ALWAYS be monitored.