Specifications
A-3
Electrical Power
Power used:
200-240VAC, 50/60 Hz, 16 Amps maximum
Required electrical circuit:
220 VAC, 20 Amps, with NEMA L6-20R locking wall receptacle (North America and Japan),
OR
220 VAC, 16 Amps, single phase, with IEC 60309 wall receptacle (Europe)
North America:
If your building receives power from a standard three-phase supply, note
that the printer will use only two of the three phases. This means that your building’s three-
phase power transformer may have an unbalanced load. Check with your electrician to ver-
ify that your building has sufficient capacity for this unbalanced load.
Optional auxiliary power for vacuum system:
Supplied 24 volt DC power supply with universal adapters, connected from the 24 VDC jack
on the vacuum/pressure assembly to either of two options:
1.
UPS
— customer-supplied uninterruptible power supply, output 100-240 VAC, 50/60 Hz,
minimum of 15 watts of power, provides battery backup to the vacuum system in the event
of a power failure.
2. Wall outlet
— 100-240 VAC, 50/60 Hz, provides temporary power to the vacuum system
when it is necessary to power down the printer for service.
Required power cord (supplied with printer):
North American (UL/CSA approved), length 8.2 feet (2.5 m),
OR
European (Harmonized), length 8.2 feet (2.5 m)
NEMA L6-20R
locking wall receptacle
(North America/Japan)
IEC 60309
wall receptacle
(Europe)
Содержание CS7075
Страница 1: ...Oc CS7075 Oc CS7100 User Manual for Oc UV curable inkjet printers 0706341 Rev B...
Страница 8: ...viii...
Страница 25: ...Workflow Overview 1 13...
Страница 28: ...1 16 Workflow Overview...
Страница 38: ...1 26 Special Features...
Страница 100: ...3 44 Media Wizard...
Страница 107: ...Auto Calibrations 4 7 Fig 4 1 Auto calibration patterns and reports...
Страница 128: ...4 28 Linearization...
Страница 138: ...5 10 Recover Missing Ink Jets...
Страница 176: ...B 16 Diagnostics...
Страница 177: ...Index 1 Index...
Страница 182: ...Index 6...