Checking Jet Health
3-9
Checking Jet Health
When AutoJet detects a missing jet, it attempts to replace it with
a working jet on the same or another printhead (in Production
and High Quality modes). In this way, printing occurs with all
jets for maximum quality.
When you notice a decrease in print quality, one or more inkjets
may be clogged. To recover clogged jets:
1.
Print a
Prime Bars
pattern to determine whether there are
any missing jets (see below).
2.
Run
AutoJet
(page 4-3) or
Manual Jet Mapping
(page 4-18).
3.
If there are any missing jets,
Print Jet-Out Lines (see
below
).
Repeat this process until all jets are working or substituted for
another jet.
Print Prime Bars
1.
From the control panel Front Page screen, press the
Prime
Bars
key.
The control panel displays a prompt asking you to enter the
total width of the prime bar pattern you wish to print.
2.
Enter a width for the prime bar pattern by pressing the
and
keys.
3.
Press the
(Proceed) key to continue.
The printer prints the prime bar pattern. The prime bars will
show correctly working jets with a solid line, and missing
jets with no line.
Map Out Missing Jets
If the Prime Bars (above) reveal a blank lines, the corresponding
jets should be mapped out. For instructions, see “AutoJet” on
page 4-3 or “Manual Jet Mapping” on page 4-18. When all miss-
ing jets have been substituted, printed output will appear as if
all jets are working.
Содержание CS7075
Страница 1: ...Oc CS7075 Oc CS7100 User Manual for Oc UV curable inkjet printers 0706341 Rev B...
Страница 8: ...viii...
Страница 25: ...Workflow Overview 1 13...
Страница 28: ...1 16 Workflow Overview...
Страница 38: ...1 26 Special Features...
Страница 100: ...3 44 Media Wizard...
Страница 107: ...Auto Calibrations 4 7 Fig 4 1 Auto calibration patterns and reports...
Страница 128: ...4 28 Linearization...
Страница 138: ...5 10 Recover Missing Ink Jets...
Страница 176: ...B 16 Diagnostics...
Страница 177: ...Index 1 Index...
Страница 182: ...Index 6...