4-12
Manual Calibrations
Manual X Head
Registration
Precise positioning of each drop of ink is essential for optimal
print quality. This is possible only if you register all printheads
in the printhead assembly to each other in the X (along the
length of the platen) direction.
This is a two-part process:
◆
Print a registration pattern.
◆
Enter the X registration data for each head.
Note
This is the manual version of AutoH2H Calibration
(see “Auto Calibrations” on page 4-6 for details).
1.
On the
Manual Calibrations
menu, press the
key repeat-
edly to highlight
Manual X Head Registration.
2.
Press the
(Menu In) key to select the option.
The control panel asks whether you want to print a manual
head-to-head calibration page.
◆
If you have a calibration pattern from a recent print, you
can use it to calibrate the heads. Press
(Cancel) and
go to the next step.
◆
If you need to print a new calibration pattern, press
(Proceed). The printer prints a calibration page.
When the calibration page has printed, the control panel
displays this prompt:
Take readings from left side of pattern.
3.
Press the
key.
The control panel displays this message:
X Direction Registration
Head 2: +0
4.
Examine the X direction pattern (in the left-hand group of
patterns) for the current head, and determine which pattern
of colored and black lines are the closest to perfectly aligned.
Содержание CS7075
Страница 1: ...Oc CS7075 Oc CS7100 User Manual for Oc UV curable inkjet printers 0706341 Rev B...
Страница 8: ...viii...
Страница 25: ...Workflow Overview 1 13...
Страница 28: ...1 16 Workflow Overview...
Страница 38: ...1 26 Special Features...
Страница 100: ...3 44 Media Wizard...
Страница 107: ...Auto Calibrations 4 7 Fig 4 1 Auto calibration patterns and reports...
Страница 128: ...4 28 Linearization...
Страница 138: ...5 10 Recover Missing Ink Jets...
Страница 176: ...B 16 Diagnostics...
Страница 177: ...Index 1 Index...
Страница 182: ...Index 6...