GATE SYSTEM INSTALLATION PROCEDURE
Printed:
10/23/2019
15-1507
OHI
OBERMEYER Hydro Inc.
3 of
36
C.
Abutment Plate Horizontal Flatness (deflection across plate)
g.1)
Left Abutment vertical at anchor bolts
g.2)
Right Abutment vertical at anchor bolts
h.1)
Left Abutment vertical middle
h.2)
Right Abutment vertical middle
i.1)
Left Abutment vertical gate up
i.2)
Right Abutment vertical gate up
g
h
i
Abutment Plate edge view
2” standoff
at edge of
plate
Measured Offset
Sketch shows section looking at top or side of abutment
plate – using a taught string line between the two
standoff points.
2” standoff
at edge of
plate
TOL/- 1/8” (3mm)
No point on each horizontal line can be more than 1/8” of true