Chapter 19: LPC11U3x/2x/1x ADC
19.6 Operation
19.6.1 Hardware-triggered conversion
If the BURST bit in the ADCR0 is 0 and the START field contains 010-111, the A/D
converter will start a conversion when a transition occurs on a selected pin or timer match
signal.
19.6.2 Interrupts
An interrupt is requested to the interrupt controller when the ADINT bit in the ADSTAT
register is 1. The ADINT bit is one when any of the DONE bits of A/D channels that are
enabled for interrupts (via the ADINTEN register) are one. Software can use the Interrupt
Enable bit in the interrupt controller that corresponds to the ADC to control whether this
results in an interrupt. The result register for an A/D channel that is generating an interrupt
must be read in order to clear the corresponding DONE flag.
19.6.3 Accuracy vs. digital receiver
While the A/D converter can be used to measure the voltage on any ADC input pin,
regardless of the pin’s setting in the IOCON block, selecting the ADC in the IOCON
registers function improves the conversion accuracy by disabling the pin’s digital receiver
(see also
).
Table 356. A/D Status Register (STAT - address 0x4001 C030) bit description
Bit
Symbol
Description
Reset
Value
7:0
DONE
These bits mirror the DONE status flags that appear in the result
register for each A/D channel n.
0
15:8
OVERRUN
These bits mirror the OVERRRUN status flags that appear in the
result register for each A/D channel n. Reading ADSTAT allows
checking the status of all A/D channels simultaneously.
0
16
ADINT
This bit is the A/D interrupt flag. It is one when any of the
individual A/D channel Done flags is asserted and enabled to
contribute to the A/D interrupt via the ADINTEN register.
0
31:17 -
Reserved. Unused, always 0.