Figure 29. Qci test case setup
8.1.3.3.1 Test SFI No Streamhandle
Qci PSFP can work for the streams without stream identify module which means streams without mac address and vid filter.
Such kind of filter setting always set larger index number stream filter entry. Those frames won't be fitlered then flow into this
stream filter entry.
Below example test no streamhandle in a stream filter, set on stream filter entry index 2 with a gate stream entry id 2. Then none
stream identifies frames would flow into the stream filter entry index 2 then pass the gate entry index 2, as shown in the following
example:
tsntool> qcisfiset --device eno0 --index 2 --gateid 2
• Streams no streamhandle should pass this filter.
tsntool> qcisfiget --device eno0 --index 2
• Send a frame from the opposite device port (ping for example).
tsntool> qcisfiget --device eno0 --index 2
• Set Stream Gate entry 2
tsntool> qcisgiset --device eno0 --index 2 --initgate 1
• Send a frame from the opposite device port.
tsntool> qcisfiget --device eno0 --index 2
NXP Semiconductors
TSN
Open Industrial User Guide, Rev. 1.8, 05/2020
User's Guide
110 / 199