FXTH870xD
Sensors
14
Freescale Semiconductor, Inc.
ADC10
The internal asynchronous ADC10 clock is always used as the conversion clock. The ADC10 can continue operation during
STOP4 mode. Conversions can be initiated while the MCU is the STOP4 mode. All ADC10 module registers contain their reset
values following exit from STOP1 mode.
LFR
When the MCU enters STOP mode the detectors in the LFR will remain powered up depending on the states of the bits selecting
the periodic sampling. Refer to
for more details.
Bandgap Reference
The bandgap reference is enabled whenever the sensor measurement interface requires sensor or voltage measurements.
TPM1
When the MCU enters STOP mode, the clock to the TPM1 module stops and the module halts operation. If the MCU is configured
to go into STOP1 mode, the TPM1 module will be reset upon wakeup from STOP and must be re-initialized.
Voltage Regulator
The voltage regulator enters a low-power standby state when the MCU enters any of the STOP modes except STOP4 (LVDSE
= 1 or ENBDM =1).
Temperature Sensor
The temperature sensor is powered up on command from the MCU.
Temperature Restart
When the MCU enters a STOP mode the temperature restart will remain powered up if the TRE bit is set. If the temperature restart
level is reached the MCU will restart from the reset vector.
3.5.5
RFM Module in STOP Modes
The RFM’s external crystal oscillator (XCO), bit rate generator, PLL, VCO, RF data buffer, data encoder, and RF output stage will
remain powered up in STOP modes during a transmission, or if the SEND bit has been set and DIRECT mode has been enabled.
RF Output
When the RFM finishes a transmission sequence the external crystal oscillator (XCO), bit rate generator, PLL, VCO, RF data
buffer, data encoder, and RF output stage will remain powered up if the SEND bit is set.
3.5.6
P-cell in STOP Modes
The P-cell is powered up only during a measurement if scheduled by the sensor measurement interface. Otherwise it is powered
down.
3.5.7
Optional g-Cell in STOP Modes
The g-cell is powered up only during a measurement if scheduled by the sensor measurement interface. Otherwise it is powered
down.
Содержание FXTH870 D Series
Страница 86: ...FXTH870xD Sensors 84 Freescale Semiconductor Inc Figure 57 Data Flow For Measurements...
Страница 170: ...FXTH870xD Sensors 168 Freescale Semiconductor Inc 19 Package Outline Figure 127 QFN Case Outline...
Страница 171: ...FXTH870xD Sensors Freescale Semiconductor Inc 169 Figure 128 QFN Case Outline...
Страница 172: ...FXTH870xD Sensors 170 Freescale Semiconductor Inc Figure 129 QFN Case Outline...
Страница 173: ...FXTH870xD Sensors Freescale Semiconductor Inc 171...