Chapter 4 - Managing and Monitoring
VT-100 Interface Enclosure Monitoring
49
If your host terminal (or program) communication settings do not match the
controller, it will not communicate. The controller has the ability to
automatically set itself to match the terminal settings.
a
After the enclosure has completed its power on self test (2 quick beeps
along with the far left three drive Status LEDs blinking amber and green),
press and hold the <Enter> key.
This process takes you to what is called the “Monitor mode.” Once in
Monitor mode (command prompt displayed), type “rs” and press <Enter>.
This will restart the controller using the corrected communication settings.
7
If the menu system does not automatically appear after the controller has
completed its boot cycle, at the screen cursor type <Control-E>. Then type
<Control-W> to switch the interface to the menu-based mode.
Main Menu Screen
8
To monitor the enclosure components, use the <Up> and <Down> Arrow
keys to select
Enclosure Information
and press <Enter>.
The screen displays the status of the internal components such as disk drives
present, temperature of the thermal sensors, cooling fan status, power supply
status, and alarm status.
4700S.book Page 49 Wednesday, April 6, 2005 2:14 PM
Содержание NexStor 4700S Series
Страница 2: ...4700S book Page 2 Wednesday April 6 2005 2 14 PM...
Страница 8: ...Table of Contents iv 4700S book Page iv Wednesday April 6 2005 2 14 PM...
Страница 74: ...Chapter 5 Troubleshooting Host SCSI Channel Problems 62 4700S book Page 62 Wednesday April 6 2005 2 14 PM...
Страница 90: ...Chapter 6 Maintenance Replacing the Enclosure 78 4700S book Page 78 Wednesday April 6 2005 2 14 PM...
Страница 94: ...Appendix A Technical Information Specifications 82 4700S book Page 82 Wednesday April 6 2005 2 14 PM...
Страница 108: ...Index 96 4700S book Page 96 Wednesday April 6 2005 2 14 PM...
Страница 109: ...4700S book Page 97 Wednesday April 6 2005 2 14 PM...