Appendix B - Port Information
DC Power Supply Connector Pinout
88
DC Power Supply Connector Pinout
CAUTION:
If the enclosure is connected to a DC power feed source that is not
within the designated -48VDC range, damage might occur to the unit.
A DC power cable is included with the 48VDC Power Supplies and is used to
connect to a DC power feed system.
NOTE:
Use only the DC power cables provided with the system.
Before connecting the cable to the source, be sure the wiring has the correct pin
out as indicated below. The connectors are Molex type, plug P/N 50-84-1060 and
female socket P/N 02-08-1002.
DC Cable Wiring Signals
Top Left
+ 48 VDC
Top Right + 48 VDC
Middle Left - 48 VDC
Middle Right - 48 VDC
Lower Left GND
Lower Right GND
Pin Signal Name
RED
RED
48VDC
48VDC
BLACK
BLACK
-48VDC
-48VDC
GREEN/YELLOW
GREEN/YELLOW
GND
GND
4700S.book Page 88 Wednesday, April 6, 2005 2:14 PM