- 21 -
■
Position Counter Clear
Clears position counter at the end of home search.
Display Option
Default
Position Clear
Disable / Enable
Enable
■
Using Over Limit Signal
To execute home search using a + direction limit signal or a - direction limit signal, set to enable. See chapter 3.3.3 for “example
of executing home search using a limit signal only”.
Display Option
Default
Using Limit Signal
Disable / Enable
Disable
■
Deviation Counter Clear Enable/Disable
The function for deviation counter clear pulse to output when encoder Z-phase rises to active in home search operation of step 3.
Display Option
Default
DCC Enable
Disable / Enable
Disable
Deviation counter clear pulse is output from OUT0 output signal (#5 pin) of CN4, 5 connectors. If this mode is enabled, OUT0
output signal cannot be used as general purpose output.
Deviation counter clear output becomes active at the same time as detection of Z-phase in step 3, and starts step 4 after finishing
clear pulse output.
■
Deviation Counter Clear Level
Specifies a logical level for deviation counter clear pulse signal.
Display Option
Default
DCC Level
0 (ON) / 1 (OFF)
0
When setting to 0, OUT0 output signal turns usually OFF and deviation counter clear pulse which turns ON is output.
When setting to 1, OUT0 output signal turns usually ON and deviation counter clear pulse which turns OFF is output.
[Note1]
To turn OUT0 output signal ON means the output transistor of the open collector turns ON.
[Note2]
The logical level is the opposite of OUT command for the driving program.
■
Deviation Counter Clear Pulse Width
Sets pulse width for deviation counter clear pulse output.
Display Option
Default
DCC Width
(μ
sec
)
10/20/100/200/1000/2000/
10000/20000
10
Selects from 10 / 20 / 100 / 200 / 1000 / 2000 / 10000 / 20000
μ
sec.