Writing of Driving Programs
Driving programs are registered in the register number 00~63. Each command display and input procedure is described below.
See chapter 4 for each command detail.
Input Procedure
Command Display
Input Operation
Description
1
Press WRT.
Status becomes command
input and ABS blinks.
2
Select command
by
↑
↓
keys.
ABS
:
INC
:
3
Press WRT.
Command is determined.
4
Input the
position data
(pulse value) by
10 keys.
Negative value can be input
by +/- keys.
5
Press
WRT.
The position data is
determined and mode is
displayed.
6
Set each mode
by +/- and
・
keys.
+/- key switches the blinking
value.
・
key shifts the selected
item.
ABS
INC
ABS Display
Absolute Position
Mode
ABS/INC 0:INC, 1:ABS
INC Display
Relative Position
ABS
INC
Drive Speed 1, 2, 3, 4
Post Timer 0, 1, 2, 3
End P 0:Disable, 1:Enable
Both 0:Disable, 1:Enable
In mode display, decimal point lights in all the digits.
7
Press WRT.
Position data flushes twice
to inform registration
completion.
1
Press WRT.
Status becomes command
input and ABS blinks.
2
Select command
by
↑
↓
keys.
Select any of HOM1 ~
HOM4.
3
Press
WRT.
Display flushes twice to
inform registration
completion.
HOM
Select any of HOM1~4 commands depends on
disable/enable of EndP (End Pulse) or Both (Y axis
simultaneously).
HOM1
End P
HOM2
HOM3
HOM4
Disable
Display
Both
Disable
Disable
Disable
Enable
Enable
Enable
Enable
Note: When Y axis, HOM3,
4 cannot be selected.
1
Press WRT.
Status becomes command
input and ABS blinks.
2
Select command
by
↑
↓
keys.
3
Press WRT.
Command is determined.
4
Input values by
10 keys.
Input numbers are
displayed from the right
side of DATA.
5
Press
WRT.
Display flushes twice to
inform registration
completion.
JMP
REP
TIM
JMP
REP
TIM
REG to Jump
Repetition Numbers
Wating Time
1
Press WRT.
Status becomes command
input and ABS blinks.
2
Select command
by
↑
↓
keys.
3
Press WRT.
Command is determined.
OUT
IJP
OTP
IJP
OUT
OTP
Output Port 0(OFF)/1(ON)
Input Port
REG to Jump
Output Port Pulse Width
4
Input the first
(left side) digit by