![Nova Electronics MR210AU Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/nova-electronics/mr210au/mr210au_user-manual_1710399058.webp)
- 53 -
7.2.2 Jog
Feed
Jog feed by the remote box operates to drive in the specified direction while pressing the key. In addition, drive speed can be
switched.
Display in Yellow
Input Key
Operation
X
+
6
X
Axis Jog Feed in the
+
direction
X
-
7
X
Axis Jog Feed in the
-
direction
Y
+
1
Y
Axis Jog Feed in the
+
direction
Y
-
2
Y
Axis Jog Feed in the
-
direction
X
SPD
8
Y
SPD
3
Drive speed switches 1, 2, 3, 4 by each pressing
the key.
Drive speed 1~4 is the values set in REG79~82.
Drive speed 0 outputs single pulse.
Press the key, the current registered speed is
displayed first, then press again, the speed is
switched.
7.2.3 Program
Execution
Registered driving programs are executed from the specified register number.
Program execution can perform for only X axis, only Y axis and for both X and Y axes simultaneously. While driving X axis, Y
axis cannot be executed and while driving Y axis, X axis cannot be executed.
Operations for program execution are as follows:
Input
Operation
Description
1
Press EXC key.
Program execution starts.
2
Press X/Y key to
specify the axis.
A selection indicator switches from X axis
→
Y axis
→
X/Y axes
by each pressing X/Y key.
3
Press 10 keys to
input the register
number.
Input the register number 0~63 to start execution by 10 keys.
4
Press EXC key.
Program execution starts.
Example: Execute X axis from the register number 10.
EXC
→
[ X/Y ]
→
1
→
0
→
EXC
If the user wants to abort program execution, press STOP key (X: 9, Y: 4).
While running, the current position of X axis is displayed; however, when X axis ends and Y axis is running, the current position
of Y axis is displayed.