Page 158 of 206 Maintenance
553-3601-220 Standard 4.00 November 1998
Replacing a defective CMCC
Note: Before replacing the CMCC, you must perform a system backup and
record the current SSN. Change the new CMCC SSN to the original
(Regression code) SSN. Perform restore.
If troubleshooting procedures indicate that the CMCC should be replaced
1.
Disable all Meridian Companion cards from the Meridian 1 side.
2.
Open the door of the IPE or CE/PE Module or expansion cabinet.
3.
Lifting the faceplate connector, unplug the faceplate cable from the
CMCC J2 slot.
4.
Remove the defective CMCC card.
5.
Remove the ROM from the defective CMCC.
6.
Install the ROM on the new CMCC.
7.
Install the new CMCC into the slot.
8.
Reconnect the faceplate connector.
9.
Reprogram the system as described in “Programming the Meridian
Companion system” on page 73 or, if you have Companion Manager
installed, perform a restore operation.
10.
Reenable the cards on the Meridian 1 side.
Replacing a defective remote power interconnect unit
If “Troubleshooting a remote power interconnect unit” on page 170 indicates
that the RPI is defective, replace it as follows:
1.
Perform an orderly shutdown of the TCM ports associated with the RPI
using the instructions in “TCM Status” on page 132.
STATIC!
Wear a grounding strap.
Do not touch the printed circuit board or the
connector. The printed circuit board is a static-
sensitive device.
Содержание Meridian Companion
Страница 2: ......
Страница 10: ...Page x of x 553 3601 220 Standard 4 00 November 1998...
Страница 106: ...Page 96 of 206 Programming the Meridian Companion system 553 3601 220 Standard 4 00 November 1998...
Страница 108: ...Page 98 of 206 Activating wireless communication 553 3601 220 Standard 4 00 November 1998...
Страница 128: ...Page 118 of 206 Programming user options 553 3601 220 Standard 4 00 November 1998...
Страница 208: ...Page 198 of 206 List of terms 553 3601 220 Standard 4 00 November 1998...
Страница 217: ......