182
Chapter 4 SMP log error messages
316806-C
Message
rcipRouteIndexRemove() - failed removing <ipaddr>, Mask= <mask>
Severity
WARNING
Description
This message is generated when removing a route index failed.
Synopsis
Freeing of route index failed.
Action
Contact customer support for further troubleshooting.
Message
rcIpRxFrame: can't signal semaphore
Severity
FATAL
Description
This is due to inability of the system to release the semaphore.
Synopsis
Unable to free semaphore.
Action
Contact customer service and have the following information available for further
analysis: system logs including any memory dumps, switch configuration, and
network topology.
Message
rcIpStart: Can't create cpu and drop next hop!
Severity
ERROR
Description
This message is generated when the system could not create the two next hop
entries in hardware- with one pointing to the CPU and the other to drop.
Synopsis
N/A
Action
Reboot the switch and contact the customer service team if the problem persists.
Message
rcIpStart: Can't create mutual-exclusion semaphore rcIpRouteLockSemId
Severity
FATAL
Description
This message is generated when an attempt to create a semaphore, used to
control re-entry to the routing process, fails.
Synopsis
Semaphore creation failed.
Action
Contact customer service and have the following information available for further
analysis: system logs including any memory dumps, switch configuration, and
network topology.
Message
rcIpStaticRouteTblSet: rcIpLoadRouteRec failed
Severity
ERROR
Description
This message is generated when MIB2 static route table entries are added and
memory is exhausted due to duplicate entries.
Synopsis
Unable to allocate memory for loading RCIP route record.
Action
Increase DRAM size and contact customer support for further troubleshooting.