162
Chapter 4 SMP log error messages
316806-C
Message
radAcctOff failed to allocate memory
Severity
ERROR
Description
This message indicates that the system is out of memory.
Synopsis
Insufficient memory.
Action
If the problem persists, contact customer support.
Message
radAcctOn failed to allocate memory
Severity
ERROR
Description
This message indicates that the system is out of memory.
Synopsis
Insufficient memory.
Action
If the problem persists, contact customer support.
Message
radAcctSendToServer can't bind UDP socket to port
Severity
ERROR
Description
This message indicates that an attempt to bind to the specified UDP port failed.
Synopsis
UDP port specified is already in use.
Action
Ensure that no other UDP service is configured on the same port. If problem
persists, contact customer support.
Message
radAcctSendToServer can't send data on UDP socket
Severity
ERROR
Description
This message indicates that the switch is unable to send a UDP packet.
Synopsis
Software error.
Action
If the problem persists, contact customer support.
Message
radAcctSendToServer cannot open socket
Severity
ERROR
Description
This message indicates the switch is unable to create a UDP socket.
Synopsis
Software error.
Action
If the problem persists, contact customer support.