Chapter 4 SMP log error messages
63
System Messaging Platform Reference Guide
Message
chCardIn: Can't read SEEPROM on slot=<value>: <value> <value>
Severity
INFO
Description
This message indicates that the SEEPROM cannot be read for the card.
Synopsis
N/A
Action
Re-insert or replace the card.
Message
chCOPListenTimerSet: global set, still setting <value>
Severity
INFO
Description
This message indicates the coprocessor listen timer is being set before it expires.
This should not happen in a normal scenario.
Synopsis
N/A
Action
N/A
Message
chProcHelloFromProc:NPAL_SetDevMac: failed for slot <value>
Severity
ERROR
Description
This message indicates a hardware write failed to set the device MAC.
Synopsis
N/A
Action
Try re-inserting the card.
Message
chRxHelloFromCOP: problem making port <value> present on slot <value>
Severity
ERROR
Description
This message indicates the port present failed for a certain port.
Synopsis
N/A
Action
Try re-inserting the card. If the problem persists, contact the customer support
team.
Message
Closed rlogin connection from <ip-address> user <user-name>
Severity
INFO
Description
This message is generated when an rlogin connection to the switch terminates.
Synopsis
N/A
Action
N/A