46
Chapter 4 SMP log error messages
316806-C
Message
aclAclTblAdd() malloc() SIZE <value> FAIL
Severity
ERROR
Description
This message indicates the system is low on resources.
Synopsis
N/A
Action
Reduce the running configuration or reboot.
Message
aclActTblAdd() malloc() SIZE <value> FAIL
Severity
ERROR
Description
This message indicates the system is low on resources.
Synopsis
N/A
Action
Reduce the running configuration or reboot.
Message
aclHwBuildPceParamBlock(): AclEntry <value> AclType <value> does not have
field selection in Profile for pkt type <value>
Severity
ERROR
Description
The template associated with the ACL does not have the fields configured for
rules in the ACL. A missing or incomplete consistency check or corruption could
cause this.
Synopsis
N/A
Action
Try removing or enabling filters on the port. Try to delete or create the ACG from
the port. Check dump using aclDumpAclTbl() or aclDumpAceList().
Message
aclHwBuildPceParamBlock(): AclEntry's AclType is NOT SUPPORTED
Severity
WARNING
Description
Two possible ACL types are IP, Non-IP. Any other value for type field indicates a
corruption or incorrect information in the instrumentation table.
Synopsis
N/A
Action
Try removing or enabling filters on the port. Try to delete or create the ACG from
the port. Check dump using aclDumpAclTbl() or aclDumpAceList().