Nortel Switched Firewall 2.3.3 User’s Guide and Command Reference
Command reference
337
213455-L, October 2005
gbcast <2-100>
This command displays the present Gratuitous Broadcast (gbcast) value and allows you
to change it. The gbcast value sets the interval between GARP messages that are sent by
the active master to ensure that all end-hosts have the correct MAC address/IP address
mapping. Increasing the gbcast value cuts down on the gbcast traffic, but lengthens the
interval between end-host ARP cache updates.
The gbcast value is multiplied by the /cfg/net/vrrp/adint value to determine the interval
in seconds between GARP messages. For example, if your adint value is 10 and your
gbcast value is 3, the interval between GARP messages will be 30 (10 x 3) seconds. The
default gbcast value is 2.
afc y|n
This command is used to enable (
y
) or disable (
n
) Advanced Failover Checking (AFC).
When AFC is enabled, the system ARPs before initiating a failover caused by missed
VRRP advertisements.
prefmaster
This command allows you to specify which Switched Firewall in the cluster is the VRRP
Master. The preferred master always remains active when it has equal or better priority.
It goes into backup mode only when its links are down and regains its position once the
links are up.
Table 61
VRRP Settings Menu (/cfg/net/vrrp) (Continued)
Command Syntax and Usage
Содержание 5100 Series Release 2.3.3
Страница 18: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 18 Preface 213455 L October 2005...
Страница 20: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 20 Getting started 213455 L October 2005...
Страница 28: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 28 Introduction 213455 L October 2005...
Страница 90: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 90 Initial setup 213455 L October 2005...
Страница 188: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 188 Redundant Firewalls 213455 L October 2005...
Страница 228: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 228 Applications 213455 L October 2005...
Страница 248: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 248 Basic system management 213455 L October 2005...
Страница 250: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 250 Command reference 213455 L October 2005...
Страница 264: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 264 The Command Line Interface 213455 L October 2005...
Страница 374: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 374 Command reference 213455 L October 2005...
Страница 376: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 376 Appendices 213455 L October 2005...
Страница 406: ...Nortel Switched Firewall 2 3 3 User s Guide and Command Reference 406 Common tasks 213455 L October 2005...