Repair
7-11
Part 106913
−
04
E
2018 Nordson Corporation
5. Wrap PTFE tape around the threads of the manifold nipple. Screw the
new valve onto the nipple. Position the valve so the final adjustment will
tighten the threads and form an air-tight seal.
6. Adjust the valve so the centerline through the nozzle and valve is
perpendicular (90
_
) to the manifold centerline (4).
7. Measure from the center of the nozzles to the outside edge of the fan
compartment opening. This distance should be 35 cm (13.75 in.) If it is
not, loosen the screws securing the manifold to the fan compartment
and adjust the manifold position. Keep the manifold parallel to the fan
compartment opening.
8. Connect the pilot air tubing to the pulse-valve tube fitting.
1
4
5
6
7
8
90
_
35 cm
(13.75 in.)
35 cm
(13.75 in.)
2
3
Figure 7-5
Pulse Valve Replacement (Horizon 400 Shown)
1. Screws
2. Lock washers
3. Flat washers
4. Manifold centerline
5. Pulse-valve tube fittings
6. Pilot air tubing
7. Pulse valves
8. Nozzles