Description
2-10
Part 106913
−
04
E
2018 Nordson Corporation
Table 2-5 Motor Starter Panel
Item
Equipment
Description
1, 10, 19
Booth mover enable
pushbutton (19)
Activates the booth mover time delay relay (1). During the
timer delay, the booth mover alarm buzzer (10) sounds, and
the system can be moved online or offline.
2, 13
Transfer pump selector
and indicator light (13)
Selects the transfer pump operation. When set to manual, the
transfer pumps run continuously. When set to auto feed, the
hopper level sensor and transfer pump time delay relay (2)
control pump operation.
3, 9
Booth lights selector (9)
NOTE:
Power to the lights must be supplied by the customer.
Activates the lighting contactor (3) for interior booth lights.
4, 5, 16
Final filter pressure
switches
Set the pressure increase that is allowed across the final
filters. At 2.5-in. wc, the final filter warning pressure switch (5)
closes and activates the final filter warning indicator light (16).
At 3-in. wc, the final filter pressure switch (4) opens and
automatically shuts down the system.
6
Pulse valve ON timer
Sets the time that pulse valves remain open after triggering.
The adjustment range is 0.05
−
0.5 sec.
7
Pulse valve OFF timer
Sets the time between cartridge filter pulses. The adjustment
range is 8
−
180 sec.
8
Pulse valve LEDs
Indicate that solenoid valves controlling the pulse valves are
open.
11
Exhauster speed
control
Used with the variable frequency drive to adjust the exhauster
fan speed.
12
Exhauster stop
pushbutton
NOTE:
This pushbutton does not shut down power to the
panel.
Shuts down the exhauster fan and system.
14
Exhauster start
pushbutton/indicator
light
Starts the exhauster fan and indicates that system power is
on.
15
System ready indicator
light
Indicates, when lit, that fire detection module limit switch and
air dryer interlocks are closed and that the system is ready to
start.
17
Main disconnect switch
Turns the motor starter panel’s electrical power on or off.
18
Sieve and non-reclaim
transfer enable
indicator lights
The sieve light indicates that the sieve is in place and running.
The non-reclaim enabled transfer light indicates that the
system can transfer powder without the sieve in place.
20
Oscillator 1 and 2
pushbuttons/indicator
lights
Turn the oscillators on or off.
Содержание HORIZON 200
Страница 4: ...Change Record ii Part 106913 04 E 2018 Nordson Corporation...
Страница 8: ......
Страница 26: ......
Страница 46: ...New Cartridge Filter Seasoning 4 4 Part 106913 04 E 2018 Nordson Corporation...
Страница 66: ...Troubleshooting 6 14 Part 106913 04 E 2018 Nordson Corporation...
Страница 94: ...Repair 7 28 Part 106913 04 E 2018 Nordson Corporation...
Страница 107: ...Parts 8 13 Part 106913 04 E 2018 Nordson Corporation 1 2 3 4 5 7 6 8 Figure 8 6 Horizon 200 400 Fan Damper Parts...
Страница 120: ...Parts 8 26 Part 106913 04 E 2018 Nordson Corporation...