Operation
3-16
Part 106913
−
04
E
2018 Nordson Corporation
powder to fluidize.
4. Start spraying parts.
5. Adjust the powder-pump air pressures and gun voltages, if necessary
(different colors or powders may require different settings).
Equipment
Recommended
Initial Settings
Final Setting
Changes
Primary Air Pressure
(plant supply)
6.2 bar (90 psi)
Collector Module
#1 Fluidizing
0.7 bar (10 psi)
#2 Fluidizing
0.7 bar (10 psi)
#3 Fluidizing
0.7 bar (10 psi)
#4 Fluidizing
0.7 bar (10 psi)
#1 Transfer Pump
1.0 bar (15 psi)
#2 Transfer Pump
1.0 bar (15 psi)
#3 Transfer Pump
1.0 bar (15 psi)
#4 Transfer Pump
1.0 bar (15 psi)
Feed Hopper — Reclaim
Fluidizing
0.5 bar (8 psi)
Vent-Assist
0.5 bar (8 psi)
Feed Hopper — Non-Reclaim
Fluidizing
0.5 bar (8 psi)
Vent-Assist
0.5 bar (8 psi)
Pulse Manifold
Air pressure
3.5
−
4.1 bar
(50
−
60 psi)
Rotary Sieve
Flowmeters
100 SCFH
Bearing Air Pressure
1.7 bar (25 psi)
Vent-assist Air Pressure
0.5 bar (8 psi)
Vibratory Sieve
Air Pressure
3.5 bar (50 psi)
Pulse Valve Timers
Delay (OFF) timer
90.0 sec
Duration (ON) timer
0.07 sec
Transfer Pump Timers
Delay timer
60 sec
Maximum Filter Pressure
Cartridge filters
4
−
6-in. wc
Final filters
1-in. wc
Содержание HORIZON 200
Страница 4: ...Change Record ii Part 106913 04 E 2018 Nordson Corporation...
Страница 8: ......
Страница 26: ......
Страница 46: ...New Cartridge Filter Seasoning 4 4 Part 106913 04 E 2018 Nordson Corporation...
Страница 66: ...Troubleshooting 6 14 Part 106913 04 E 2018 Nordson Corporation...
Страница 94: ...Repair 7 28 Part 106913 04 E 2018 Nordson Corporation...
Страница 107: ...Parts 8 13 Part 106913 04 E 2018 Nordson Corporation 1 2 3 4 5 7 6 8 Figure 8 6 Horizon 200 400 Fan Damper Parts...
Страница 120: ...Parts 8 26 Part 106913 04 E 2018 Nordson Corporation...