© 2022 Nordson Corporation
5-3
Replacing A Card
If replacing an existing card, turn off the booth exhaust fan first, then replace the card.
When turning on the booth exhaust fan, the green watchdog LED should blink. Since
the card ID has changed, the red fault LED on the card will light and a fault message will
appear on the Alarm screen. To reset the fault LED, open the Alarm screen and touch the
Clear All Faults button.
1
2
3
4
5
6
Spray Gun Connector
Configuration on Card
17 19 21 23 25 27 29 31
18 20 22 24 26 28 30 32
2 4 6 8 10 12 14 16
1 3 5 7 9 11 13 15
Figure 5-1 Spray Gun Control Card Replacement
1. Card cage (slot 1)
2. Gun control card
3. Spray gun 2 connector
4. Spray gun 1 connector
5. Locking tab
6. Backplane