Code
Message Text
Description
Refer to
Page
2108
Speed calculated greater
than maximum
The speed of the reciprocator is greater than the maximum
value allowed.
2113
Reciprocator not in ready
state for Color Change
The reciprocator is not in the proper position for color change. page 4-26
300x
Watchdog
3100
Positioner Watchdog fault
The remote Ethernet device did not respond with a watchdog
signal in 1 second.
3200
Reciprocator Watchdog fault The remote Ethernet device did not respond with a watchdog
signal in 1 second.
410x
Color Change
4109
Clean cycle aborted arch
clean operation − waiting on
park release
Clean cycle detected an abort − waiting for user to press park
to release.
4110
Clean cycle aborted by
user action − park release
detected
Clean cycle aborted by user − part release was detected.
4111
Clean cycle aborted
detected machine lockout/
watchdog
A machine malfunction aborted the cleaning operation.
CAN Network Errors
Table 4-2 CAN Network Messages
Error
Code
Message
Cause/Correction
101
CAN bus fault detected
Hardware error. Check the CAN cable for shorts. If the cable is good,
replace the CAN card.
102
CAN receive buffer overflow
Host CAN interface received too much data and could not process it
quickly enough. Reboot the system.
103
Message timeout
Remote CAN device did not respond to a direct request in the allotted
time. Check the spray gun card or iFlow card.
104
Went offline
Normal operational message. The user will see this message if the
booth exhaust fan is shut off, which removes power from spray gun
cards, or if the spray gun card is disconnected, or if the iFlow module is
disconnected from the CAN network.
105
Returned to online
Normal operational message. No action required.
107
Communications errors
These error messages indicate that communications on the iControl
2 CAN bus may be having problems. Troubleshooting should include
verification of all CAN cable connections and grounding, and spray gun
cable connections and continuity. CAN errors can also be caused by
individual spray gun cards or the iControl 2 PC to CAN card interface.
These errors do not indicate a specific device failure as all devices are in
parallel on the CAN bus.
108
109
110
111
112
113
Содержание Encore HD iControl 2
Страница 6: ...2022 Nordson Corporation 1609758 04 iv Table of Contents...
Страница 8: ...2022 Nordson Corporation 1609758 04 ii Change Record...
Страница 84: ...2022 Nordson Corporation 1609758 04 4 34 Troubleshooting...
Страница 102: ...2022 Nordson Corporation 1609758 04 6 12 Parts...
Страница 104: ...2022 Nordson Corporation 1609758 04 7 2 Drawings...
Страница 105: ......
Страница 106: ......
Страница 107: ......
Страница 108: ......
Страница 109: ......
Страница 110: ......
Страница 113: ......
Страница 114: ......