© 2022 Nordson Corporation
4-32
Calibration with a Mouse
WARNING:
Do not spray powder while the console door is open. Shut off the booth
exhaust fan to remove switched power from the console and prevent spray gun opera-
tion while performing this procedure. Failure to observe this warning could create a
hazardous condition and could result in personal injury or property damage.
Use this procedure to recalibrate the touch screen if unable to touch the CAL button or
the buttons on the iControl 2 screens, or if installing a program card previously used in
another iControl 2 console.
1.
Turn off the iControl 2 console power.
2. Open the iControl 2 console door and connect a USB mouse to the iControl 2 PC.
3. Turn on power and allow the operating system to load. The CAL button is displayed
on the touch screen before the iControl 2 software loads.
4. Use the mouse to move the cursor to the CAL button and click on it. The touch screen
calibration procedure starts.
NOTE:
If the CAL button was missed, allow the iControl 2 software to load, then, if
possible, open the System Configuration screen and touch the Program Shutdown
button. When the operating system shutdown prompt appears on the screen, touch the
Cancel button, then the CAL button. If unable to touch any buttons on the screen, then
cycle the console power and try again (go back to Step 1).
5. Once the calibration procedure starts, USE YOUR FINGER, NOT THE MOUSE, to
touch the calibration targets, following the instructions on the screen carefully. When
you have completed the calibration procedure, touch the iControl 2 button to start the
iControl 2 software.
6.
Test the touch screen calibration, then perform a program shutdown, turn off console
power, and disconnect the mouse. Close the iControl 2 cabinet door before restarting
the system.
No Touch Screen Display
Check the following:
• Check the power LED on the front bezel below the screen. If the LED is not lit then the
PC is not powered up.
• Make sure the system power switch is on.
• Make sure the video and serial cables between the PC and the touch screen is
connected.
Have an electrician check the following:
• Console fuses on the DIN rail, at the incoming power terminals
• Unswitched power connections to the fuse blocks
• Power supply to the console
• 12 Vdc supply to the touch screen
• 24 Vdc supply to the PC
Содержание Encore HD iControl 2
Страница 6: ...2022 Nordson Corporation 1609758 04 iv Table of Contents...
Страница 8: ...2022 Nordson Corporation 1609758 04 ii Change Record...
Страница 84: ...2022 Nordson Corporation 1609758 04 4 34 Troubleshooting...
Страница 102: ...2022 Nordson Corporation 1609758 04 6 12 Parts...
Страница 104: ...2022 Nordson Corporation 1609758 04 7 2 Drawings...
Страница 105: ......
Страница 106: ......
Страница 107: ......
Страница 108: ......
Страница 109: ......
Страница 110: ......
Страница 113: ......
Страница 114: ......