Internal Capacities
Freezer (2) volume
----------------------------------------------------------------------------
1.3 cu.ft. each
Fresh food compartment volume -------------------------------------------------------------------8.0 cu.ft.
Controls
Type ------------------------------------------------------------------ Electronic with built-in self diagnostic
ON/OFF/MODE/TEMP SET switches
------------------
Overlay assembly with flush-pushbuttons
Temperature setting range ------------------------------------------------------------
1=cold to 9=coldest
Temperature sensing device ----------------------------------------------------------------------Thermistor
Off-level operating limits
Side-to-side
------------------------------------------------------------
3 degrees maximum at refrigerator
Front-to-back ----------------------------------------------------------
6 degrees maximum at refrigerator
DC power
Electronic controls voltage requirement -----------------------------------------------
10.5 to 15.4 VDC
DC fuse F1 (in power board
-----------------------------------
5 A (tan color), automotive blade style
DC amperage draw
@
nominal 12 VDC
Automatic ignition
------------------------------------------------------------------------------------------
0.50 A
Divider heater ----------------------------------------------------------------------------------------------
0.70 A
Flapper heater ----------------------------------------------------------------------------------------------
0.42 A
Lamp, fresh food compartment -------------------------------------------------------------------------
0.46 A
Gas valve --------------------------------------------------------------------------------------------------
0.146 A
Fans (2)
----------------------------------------------------------------------------------------
0.400 A (per fan)
Valve, water dispenser
---------------------------------------------------------------------
10 W @ 12 VDC
Heater, water dispenser models water line ----------------------------------------------------------
0.44 A
Heater, ice maker only water line ------------------------------------------------------------------------
1.3 A
Heater, modular ice maker and water dispenser --------------------------------------------------
0.23 A
AC components
AC heaters
----------------------------------------------------------------------------------------------------------2
Wattage, per heater ----------------------------------------------------------------------
225 W @ 120 VAC
Heater resistance @ ambient temperature (per heater)
-------------------------------------------64
Ω
AUTO and AC manual mode operation voltage requirement
----------------------
108 to 132 VAC
AC fuse F2 (in power board)
------------------------------
8 A,
1/4
in. x 1
1/4
in. AGC style, fast acting
Ice maker (IM models only)
------------------------------------------------------------
180 W @ 115 VAC
Water valve, ice maker (IM and IMD models only)
---------------------------------
10 W @ 115 VAC
LP gas (propane)
Operating pressure ----------------------------------------------------------------------10.5 to 11.5 in. w. c.
Btu/hr 7-slot burner / LP 18 orifice
--------------------------------------------
2400 Btu/hr @ 11 in. w. c
Flame sensing ------------------------------------------------
Electronic through spark/sense electrode
Electrode tip-to-burner air gap -------------------------------------------------------------------
1/8
to
3/16
in.
s
ection
2 —s
pecificAtions
Содержание 121X series
Страница 2: ...This page intentionally left blank...
Страница 10: ...8 Section 2 This page intentionally left blank...
Страница 96: ...94 Section 12 Section 12 Wiring Diagrams and Pictorials Figure 12 1 Wiring diagram...
Страница 97: ...Section 12 95 Figure 12 2 Wiring pictorial...
Страница 99: ...Section 12 97 This page intentionally left blank...