AC HE Code— AC Heaters Failed Open
MODE
ON/OFF
SET TEMP
on
1 COLD-
9 COLDEST
1 COLD-
9 COLDEST
Begin
Are heaters connected correctly
to the power board?
1
Resistance 58 to 68 ohms?
2
Connect the heaters to power board.
Black wire leads terminals to AC_HT_
LO and AC_HT_LO_2
Yellow wire leads terminal to AC_HT_
HI and AC_HT_HI_2
NO
Check each heater resistance. Resis-
tance range is 58 to 68 ohms.
YES
NO
Replace heaters.
Replace power board.
The AC HE fault is recorded in either the AUTO or Manual AC mode. The following may
apply.
AUTO MODE: When AC heaters current input falls below 0.5 amperes and AUTO LP has
locked out, the fault is set and recorded to non volatile memory approximately 25 seconds
after it occurs, providing there is a call for cooling.
AC manual mode: When AC heater current input falls below 0.5 amperes, the fault is set
and recorded to non volatile memory approximately 25 seconds it occurs, provided there is
a call for cooling
IMPORTANT
YES