FL – – Code — Flame Present with Gas Off
Begin
Flame on?
1
Voltage present at coil?
2
Flame sense circuit malfunction.
Replace power board.
NO
Check for DC voltage at gas valve solenoid
terminals.
YES
Gas valve leaking internally or stuck open.
Replace gas valve.
Replace power board.
NO
YES
The FL -- fault is recorded in all operating modes any time a flame is sensed at the burner
when is not supposed to be lit. The FL -- fault displays and is recorded in non volatile
memory approximately 25 seconds after it occurs.