S
ection
5
43
Measuring Solenoid Coil Resistance
Tools:
Multimeter
To measure solenoid coil resistance.
1. Turn off the refrigerator.
2. Disconnect wires at the solenoid coil
connections.
3. Set multimeter to the Ohm function.
4. Connect multimeter probes to the solenoid
coil terminals as illustrated in Figure 5-4.
—Coil resistance should be within 77 and
85 ohms.
Burner Tube Assembly
The burner tube is 1/4 inch OD aluminum
tubing The anti-vibration loop absorbs vibration
to prevent metal fatigue. Each end of the tube
ends in a double flare. The burner tube is
illustrated in Figure 5-5.
Figure 5-4. —Checking solenoid coil resistance.
Figure 5-5. —Burner tube assembly.
Double flared
Burner connection fitting
Anti vibration loop
Gas valve connection fitting
Double flared