L1 oP Code—Open High Temperature Limit Switch
The L1 oP indicates the high temperature limit switch is open or disconnected. The switch
is located on the cooling system canister. It is designed to open when the cooling system
boiler temperature exceeds 378 degrees Fahrenheit (192.2 degrees Celsius).
On units with non-resettable switch, replace the switch with a resettable switch. On units
with resettable switches, reset the switch. In both cases troubleshoot for the L1 oP fault
cause.
IMPORTANT
MODE
ON/OFF
SET TEMP
on
1 COLD-
9 COLDEST
1 COLD-
9 COLDEST
Begin
Refrigerator cooling before L1 Op
fault displayed?
1
Burner overheated (Blue)?
2
1. Replace/reset the high temperature
limit switch.
2. Test cooling system performance on AC
and LP gas operation.
NO
YES
Heat deflector cap and/or burner box
blocked with insulation?
3
YES
YES
Go to page 28
NO
NO
IMPORTANT
Make sure refrigerator is operating
within level requirements.
1. Clear insulation.
2. Replace/reset the high temperature
limit switch.
3. Set controls to LP operation and test
cooling system performance.
Содержание 121X series
Страница 2: ...This page intentionally left blank...
Страница 10: ...8 Section 2 This page intentionally left blank...
Страница 96: ...94 Section 12 Section 12 Wiring Diagrams and Pictorials Figure 12 1 Wiring diagram...
Страница 97: ...Section 12 95 Figure 12 2 Wiring pictorial...
Страница 99: ...Section 12 97 This page intentionally left blank...