37
Figure 4-5. —Sidewall venting - Enclosure depth more than 24 in. and less than 26 in.
Aluminum or galvanized steel sheet
full width of enclosure.
Aluminum or galvanized steel sheet
full width baffle.
Fans
621156 Vent.
Minimum distance between the
bottom of the enclosure and the top
of the upper vent o 62 in.
Vent even or below enclosure floor.
Enclosure depths of more than
24 in. and less then 26 in.
Bend of baffle flush with bottom edge of
vent door frame.
621156 Vent - Aligned horizontally with
lower vent.
Distance between bottom of
condenser fins and top of baffle
0 - 1/4 in.
Opening between condenser fins
and baffle 0 - 1/4 in.
Distance between inner wall and
cooling system less than 2 in.
0 - 1/4 in.
0 - 1 in.